-- extracted from rfc2864.txt
-- at Tue Jun 27 07:07:44 2000
IF-INVERTED-STACK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
mib-2
FROM SNMPv2-SMI
RowStatus
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
ifStackGroup2,
ifStackHigherLayer,
ifStackLowerLayer
FROM IF-MIB;
ifInvertedStackMIB MODULE-IDENTITY
LAST-UPDATED "200006140000Z" -- Jun 14, 2000 12:00:00 AM
ORGANIZATION "IETF Interfaces MIB Working Group"
CONTACT-INFO
"Keith McCloghrie
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
US
408-526-5260
kzm@cisco.com"
DESCRIPTION
"The MIB module which provides the Inverted Stack Table for
interface sub-layers."
REVISION "200006140000Z" -- Jun 14, 2000 12:00:00 AM
DESCRIPTION
"Initial revision, published as RFC 2864"
-- 1.3.6.1.2.1.77 -- ::= { mib-2 77 }
ifInvMIBObjects OBJECT IDENTIFIER
-- 1.3.6.1.2.1.77.1 -- ::= { ifInvertedStackMIB 1 }
--
-- The Inverted Interface Stack Group
--
ifInvStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfInvStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information on the relationships between
the multiple sub-layers of network interfaces. In
particular, it contains information on which sub-layers run
'underneath' which other sub-layers, where each sub-layer
corresponds to a conceptual row in the ifTable. For
example, when the sub-layer with ifIndex value x runs
underneath the sub-layer with ifIndex value y, then this
table contains:
ifInvStackStatus.x.y=active
For each ifIndex value, z, which identifies an active
interface, there are always at least two instantiated rows
in this table associated with z. For one of these rows, z
is the value of ifStackHigherLayer; for the other, z is the
value of ifStackLowerLayer. (If z is not involved in
multiplexing, then these are the only two rows associated
with z.)
For example, two rows exist even for an interface which has
no others stacked on top or below it:
ifInvStackStatus.z.0=active
ifInvStackStatus.0.z=active
This table contains exactly the same number of rows as the
ifStackTable, but the rows appear in a different order."
REFERENCE
"ifStackTable of RFC 2863"
-- 1.3.6.1.2.1.77.1.1 -- ::= { ifInvMIBObjects 1 }
ifInvStackEntry OBJECT-TYPE
SYNTAX IfInvStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information on a particular relationship between two sub-
layers, specifying that one sub-layer runs underneath the
other sub-layer. Each sub-layer corresponds to a conceptual
row in the ifTable."
INDEX {
ifStackLowerLayer,
ifStackHigherLayer }
-- 1.3.6.1.2.1.77.1.1.1 -- ::= { ifInvStackTable 1 }
IfInvStackEntry ::= SEQUENCE {
ifInvStackStatus RowStatus }
ifInvStackStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the relationship between two sub-layers.
An instance of this object exists for each instance of the
ifStackStatus object, and vice versa. For example, if the
variable ifStackStatus.H.L exists, then the variable
ifInvStackStatus.L.H must also exist, and vice versa. In
addition, the two variables always have the same value.
However, unlike ifStackStatus, the ifInvStackStatus object
is NOT write-able. A network management application wishing
to change a relationship between sub-layers H and L cannot
do so by modifying the value of ifInvStackStatus.L.H, but
must instead modify the value of ifStackStatus.H.L. After
the ifStackTable is modified, the change will be reflected
in this table."
-- 1.3.6.1.2.1.77.1.1.1.1 -- ::= { ifInvStackEntry 1 }
-- conformance information
ifInvConformance OBJECT IDENTIFIER
-- 1.3.6.1.2.1.77.1.2 -- ::= { ifInvMIBObjects 2 }
ifInvGroups OBJECT IDENTIFIER
-- 1.3.6.1.2.1.77.1.2.1 -- ::= { ifInvConformance 1 }
ifInvCompliances OBJECT IDENTIFIER
-- 1.3.6.1.2.1.77.1.2.2 -- ::= { ifInvConformance 2 }
-- compliance statements
ifInvCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which provide
inverted information on the layering of network interfaces."
MODULE
MANDATORY-GROUPS {
ifInvStackGroup }
OBJECT ifInvStackStatus
SYNTAX INTEGER {
active(1) }
DESCRIPTION
"Support is only required for 'active'."
MODULE IF-MIB
MANDATORY-GROUPS {
ifStackGroup2 }
-- 1.3.6.1.2.1.77.1.2.2.1 -- ::= { ifInvCompliances 1 }
-- units of conformance
ifInvStackGroup OBJECT-GROUP
OBJECTS {
ifInvStackStatus }
STATUS current
DESCRIPTION
"A collection of objects providing inverted information on
the layering of MIB-II interfaces."
-- 1.3.6.1.2.1.77.1.2.1.1 -- ::= { ifInvGroups 1 }
END
--
-- Copyright (C) The Internet Society (2000). All Rights Reserved.
--
-- This document and translations of it may be copied and furnished to
-- others, and derivative works that comment on or otherwise explain it
-- or assist in its implementation may be prepared, copied, published
-- and distributed, in whole or in part, without restriction of any
-- kind, provided that the above copyright notice and this paragraph are
-- included on all such copies and derivative works. However, this
-- document itself may not be modified in any way, such as by removing
-- the copyright notice or references to the Internet Society or other
-- Internet organizations, except as needed for the purpose of
-- developing Internet standards in which case the procedures for
-- copyrights defined in the Internet Standards process must be
-- followed, or as required to translate it into languages other than
-- English.
--
-- The limited permissions granted above are perpetual and will not be
-- revoked by the Internet Society or its successors or assigns.
--
-- This document and the information contained herein is provided on an
-- "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
-- TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
-- BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
-- HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
-- MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--