-- extracted from rfc2954.txt
-- at Tue Oct 17 07:11:19 2000

FRNETSERV-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
        transmission,
        Counter32,
        Integer32
                FROM SNMPv2-SMI
        TimeStamp,
        RowStatus
                FROM SNMPv2-TC
        MODULE-COMPLIANCE,
        OBJECT-GROUP,
        NOTIFICATION-GROUP
                FROM SNMPv2-CONF
        InterfaceIndex,
        ifIndex
                FROM IF-MIB
        SnmpAdminString
                FROM SNMP-FRAMEWORK-MIB;

frnetservMIB MODULE-IDENTITY
        LAST-UPDATED "200009280000Z"       -- Sep 28, 2000 12:00:00 AM
        ORGANIZATION "IETF Frame Relay Service MIB Working Group"
        CONTACT-INFO
               "WG Charter:
                  http://www.ietf.org/html.charters/frnetmib-charter
                WG-email:
                  frnetmib@sunroof.eng.sun.com

                Subscribe:
                  frnetmib-request@sunroof.eng.sun.com
                Email Archive:
                  ftp://ftp.ietf.org/ietf-mail-archive/frnetmib

                Chair:      Andy Malis
                            Vivace Networks, Inc.
                Email:      Andy.Malis@vivacenetworks.com

                WG editor:  Kenneth Rehbehn
                            Megisto Systems, Inc.
                Email:      krehbehn@megisto.com

                Co-author:  David Fowler
                            Syndesis Limited,
                EMail:      fowler@syndesis.com"
        DESCRIPTION
               "The MIB module to describe generic objects for
                Frame Relay Network Service."
        REVISION "200009280000Z"   -- Sep 28, 2000 12:00:00 AM
        DESCRIPTION
               "Published as RFC 2954.

                The major new features of this revision include:

                    o  Support for read-write capability to
                       provision switch components providing service,

                    o  Support for cross-connection via a frame relay
                       to ATM service interworking function,

                    o  Support for frame relay fragmentation,

                    o  Additional frame counters to track frame
                       loss.

                Refer to Appendix A for a comprehensive list of
                changes since RFC 1604."
        REVISION "199311161200Z"   -- Nov 16, 1993 12:00:00 PM
        DESCRIPTION
               "Published as RFC 1604."
 -- 1.3.6.1.2.1.10.44 --  ::= { transmission 44 }


frnetservObjects OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.10.44.1 --  ::= { frnetservMIB 1 }

frnetservTraps OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.10.44.2 --  ::= { frnetservMIB 2 }

frnetservTrapsPrefix OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.10.44.2.0 --  ::= { frnetservTraps 0 }

--
-- The Frame Relay Service Logical Port
--

frLportTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FrLportEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The Frame Relay Logical Port Information table is
                an interface-specific addendum to the generic
                ifTable of the Interface MIB."
 -- 1.3.6.1.2.1.10.44.1.1 --  ::= { frnetservObjects 1 }


frLportEntry OBJECT-TYPE
        SYNTAX FrLportEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry in the Frame Relay Logical Port
                Information table."
        INDEX {
                ifIndex }
 -- 1.3.6.1.2.1.10.44.1.1.1 --  ::= { frLportTable 1 }


FrLportEntry ::= SEQUENCE {
        frLportNumPlan            INTEGER,
        frLportContact            SnmpAdminString,
        frLportLocation           SnmpAdminString,
        frLportType               INTEGER,
        frLportAddrDLCILen        INTEGER,
        frLportVCSigProtocol      INTEGER,
        frLportVCSigPointer       OBJECT IDENTIFIER,
        frLportDLCIIndexValue     Integer32,
        frLportTypeAdmin          INTEGER,
        frLportVCSigProtocolAdmin INTEGER,
        frLportFragControl        INTEGER,
        frLportFragSize           Integer32 }


frLportNumPlan OBJECT-TYPE
        SYNTAX INTEGER {
                        other(1),
                        e164(2),
                        x121(3),
                        none(4) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the network
                address numbering plan for this UNI/NNI logical
                port. The network address is the object
                ifPhysAddress. The value none(4) implies that
                there is no ifPhysAddress.  The FRS agent will
                return an octet string of zero length for
                ifPhysAddress.  The value other(1) means that an
                address has been assigned to this interface, but
                the numbering plan is not enumerated here."
        REFERENCE

               "E.164 [29]
                X.121 [30]"
 -- 1.3.6.1.2.1.10.44.1.1.1.1 --  ::= { frLportEntry 1 }


frLportContact OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the network
                contact for this UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.1.1.1.2 --  ::= { frLportEntry 2 }


frLportLocation OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the frame
                relay network location for this UNI/NNI logical
                port."
 -- 1.3.6.1.2.1.10.44.1.1.1.3 --  ::= { frLportEntry 3 }


frLportType OBJECT-TYPE
        SYNTAX INTEGER {
                        uni(1),
                        nni(2) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the type of
                network interface for this logical port."
 -- 1.3.6.1.2.1.10.44.1.1.1.4 --  ::= { frLportEntry 4 }


frLportAddrDLCILen OBJECT-TYPE
        SYNTAX INTEGER {
                        twoOctets10Bits(1),
                        threeOctets10Bits(2),
                        threeOctets16Bits(3),
                        fourOctets17Bits(4),
                        fourOctets23Bits(5) }
        UNITS
               "Octets"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Q.922
                Address field length and DLCI length for this
                UNI/NNI logical port."
        REFERENCE

               "Q.922 [25]"
 -- 1.3.6.1.2.1.10.44.1.1.1.5 --  ::= { frLportEntry 5 }


frLportVCSigProtocol OBJECT-TYPE
        SYNTAX INTEGER {
                        none(1),
                        lmi(2),
                        ansiT1617D(3),
                        ansiT1617B(4),
                        ccittQ933A(5) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Local
                                    In-Channel Signaling Protocol that is used for
                                    this frame relay UNI/NNI logical port.

                                    none(1):        Interface does not use a PVC
                                                    signaling protocol

                                    lmi(2):         Interface operates the Stratacom/
                                                    Nortel/DEC Local Management
                                                    Interface Specification protocol

                                    ansiT1617D(3):  Interface operates the ANSI T1.617
                                                    Annex D PVC status protocol

                                      ansiT1617B(4):  Interface operates the ANSI
                T1.617
                                                      Annex B procedures

                                      ccittQ933A(5):  Interface operates the ITU Q.933
                                                      Annex A PVC status protocol"
        REFERENCE

               "LMI [24]
                T1.617 Annex D [17],
                Q.933 Annex A [22]"
 -- 1.3.6.1.2.1.10.44.1.1.1.6 --  ::= { frLportEntry 6 }


frLportVCSigPointer OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        MAX-ACCESS read-only
        STATUS deprecated
        DESCRIPTION
               "The value of this object is used as a pointer to
                the table that contains the Local In-Channel
                Signaling Protocol parameters and errors for this
                UNI/NNI logical port.

                This object has been deprecated to reflect the
                fact that the local in-channel signaling
                parameters are accessed from a single table
                (frMgtVCSigTable) that includes parameters for all
                possible signaling protocols.  Early design
                anticipated multiple tables, one for each
                signaling protocol."
 -- 1.3.6.1.2.1.10.44.1.1.1.7 --  ::= { frLportEntry 7 }


frLportDLCIIndexValue OBJECT-TYPE
        SYNTAX Integer32 (16..4194303)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "This object contains a hint to be used for
                frPVCEndptDLCIIndex when creating entries in the
                frPVCEndptTable.  The SYNTAX of this object
                matches the SYNTAX of the frPVCEndptDLCIIndex - an
                object that is restricted to legal Q.922 DLCI
                values for the size of the address field.

                The value 0 indicates that no unassigned entries
                are available.

                To obtain the frPVCEndptDLCIIndex value for a new
                entry, the manager issues a management protocol
                retrieval operation to obtain the current value of
                this object.  After each retrieval, the agent must
                modify the value to the next unassigned index to
                prevent assignment of the same value to multiple
                management systems.

                A management system should repeat the read to
                obtain a new value should an attempt to create the
                new row using the previously returned hint fail."
        REFERENCE

               "Q.922 [25]"
 -- 1.3.6.1.2.1.10.44.1.1.1.8 --  ::= { frLportEntry 8 }


frLportTypeAdmin OBJECT-TYPE
        SYNTAX INTEGER {
                        uni(1),
                        nni(2) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object desired identifies the
                type of network interface for this logical port."
 -- 1.3.6.1.2.1.10.44.1.1.1.9 --  ::= { frLportEntry 9 }


frLportVCSigProtocolAdmin OBJECT-TYPE
        SYNTAX INTEGER {
                        none(1),
                        lmi(2),
                        ansiT1617D(3),
                        ansiT1617B(4),
                        ccittQ933A(5) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                Local In-Channel Signaling Protocol that is used
                for this frame relay UNI/NNI logical port.  This
                value must be made the active protocol as soon as
                possible on the device.

                Refer to frLportVCSigProtocol for a description of
                each signaling protocol choices."
        REFERENCE

               "LMI [24]
                T1.617 Annex D [17],
                Q.933 Annex A [22]"
 -- 1.3.6.1.2.1.10.44.1.1.1.10 --  ::= { frLportEntry 10 }


frLportFragControl OBJECT-TYPE
        SYNTAX INTEGER {
                        on(1),
                        off(2) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "This object controls the transmission and
                reception of fragmentation frames for this UNI or
                NNI interface.

                on(1)   Frames are fragmented using the interface
                        fragmentation format
                        Note:  The customer side of the interface
                        must also be configured to fragment
                        frames.

                off(2)  Frames are not fragmented using the
                        interface fragmentation format."
        REFERENCE

               "FRF.12 [21]"
        DEFVAL { off }
 -- 1.3.6.1.2.1.10.44.1.1.1.11 --  ::= { frLportEntry 11 }


frLportFragSize OBJECT-TYPE
        SYNTAX Integer32 (0..4096)
        UNITS
               "Octets"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object is the size in octets of
                the maximum size of each fragment to be sent when
                fragmenting.  This object is only used by the
                fragmentation transmitter, and the two sides of
                the interface may differ.  The fragment size
                includes the octets for the frame relay header,
                the UI octet, the NLPID, the fragmentation header,
                and the fragment payload. If frLportFragControl is
                set to off, this value should be zero."
        REFERENCE

               "FRF.12 [21]"
        DEFVAL { 0 }
 -- 1.3.6.1.2.1.10.44.1.1.1.12 --  ::= { frLportEntry 12 }


--
-- Frame Relay Management VC Signaling
--

frMgtVCSigTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FrMgtVCSigEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The Frame Relay Management VC Signaling
                Parameters and Errors table."
 -- 1.3.6.1.2.1.10.44.1.2 --  ::= { frnetservObjects 2 }


frMgtVCSigEntry OBJECT-TYPE
        SYNTAX FrMgtVCSigEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry in the Frame Relay Management VC
                Signaling Parameters Errors table."
        INDEX {
                ifIndex }
 -- 1.3.6.1.2.1.10.44.1.2.1 --  ::= { frMgtVCSigTable 1 }


FrMgtVCSigEntry ::= SEQUENCE {
        frMgtVCSigProced            INTEGER,
        frMgtVCSigUserN391          INTEGER,
        frMgtVCSigUserN392          INTEGER,
        frMgtVCSigUserN393          INTEGER,
        frMgtVCSigUserT391          INTEGER,
        frMgtVCSigNetN392           INTEGER,
        frMgtVCSigNetN393           INTEGER,
        frMgtVCSigNetT392           INTEGER,
        frMgtVCSigNetnN4            INTEGER,
        frMgtVCSigNetnT3            INTEGER,
        frMgtVCSigUserLinkRelErrors Counter32,
        frMgtVCSigUserProtErrors    Counter32,
        frMgtVCSigUserChanInactive  Counter32,
        frMgtVCSigNetLinkRelErrors  Counter32,
        frMgtVCSigNetProtErrors     Counter32,
        frMgtVCSigNetChanInactive   Counter32,
        frMgtVCSigProcedAdmin       INTEGER,
        frMgtVCSigUserN391Admin     INTEGER,
        frMgtVCSigUserN392Admin     INTEGER,
        frMgtVCSigUserN393Admin     INTEGER,
        frMgtVCSigUserT391Admin     INTEGER,
        frMgtVCSigNetN392Admin      INTEGER,
        frMgtVCSigNetN393Admin      INTEGER,
        frMgtVCSigNetT392Admin      INTEGER,
        frMgtVCSigNetnT3Admin       INTEGER }


frMgtVCSigProced OBJECT-TYPE
        SYNTAX INTEGER {
                        u2nnet(1),
                        bidirect(2),
                        u2nuser(3) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the local
                in-channel signaling procedural role that is used
                for this UNI/NNI logical port.  Bidirectional
                procedures implies that both user-side and
                network-side procedural roles are used.

                u2nnet(1)   Logical port operates user to network
                            procedure in the role of the network
                            side

                bidirect(2) Logical port operates the
                            bidirectional procedure (both user
                            and network side roles)

                u2nuser(3)  Logical port operates user to network
                            procedure in the role of the user
                            side"
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
 -- 1.3.6.1.2.1.10.44.1.2.1.1 --  ::= { frMgtVCSigEntry 1 }


frMgtVCSigUserN391 OBJECT-TYPE
        SYNTAX INTEGER (1..255)
        UNITS
               "Polls"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the User-side
                N391 full status polling cycle value for this
                UNI/NNI logical port.  If the logical port is not
                performing user-side (bidirectional) procedures,
                then this object is not instantiated and an
                attempt to read will result in the noSuchInstance
                exception response."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
        DEFVAL { 6 }
 -- 1.3.6.1.2.1.10.44.1.2.1.2 --  ::= { frMgtVCSigEntry 2 }


frMgtVCSigUserN392 OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the User-side
                N392 error threshold value for this UNI/NNI
                logical port.  If the logical port is not
                performing user-side (bidirectional) procedures,
                then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
        DEFVAL { 3 }
 -- 1.3.6.1.2.1.10.44.1.2.1.3 --  ::= { frMgtVCSigEntry 3 }


frMgtVCSigUserN393 OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the User-side
                N393 monitored events count value for this UNI/NNI
                logical port.  If the logical port is not
                performing user-side (bidirectional) procedures,
                then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
        DEFVAL { 4 }
 -- 1.3.6.1.2.1.10.44.1.2.1.4 --  ::= { frMgtVCSigEntry 4 }


frMgtVCSigUserT391 OBJECT-TYPE
        SYNTAX INTEGER (5..30)
        UNITS
               "Seconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the User-side
                T391 link integrity verification polling timer
                value for this UNI/NNI logical port.  If the
                logical port is not performing user-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
        DEFVAL { 10 }
 -- 1.3.6.1.2.1.10.44.1.2.1.5 --  ::= { frMgtVCSigEntry 5 }


frMgtVCSigNetN392 OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Network-
                side N392 error threshold value (nN2 for LMI) for
                this UNI/NNI logical port.  If the logical port is
                not performing network-side procedures, then this
                object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17],
                LMI [24]"
        DEFVAL { 3 }
 -- 1.3.6.1.2.1.10.44.1.2.1.6 --  ::= { frMgtVCSigEntry 6 }


frMgtVCSigNetN393 OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Network-
                side N393 monitored events count value (nN3 for
                LMI) for this UNI/NNI logical port.  If the
                logical port is not performing network-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17],
                LMI [24]"
        DEFVAL { 4 }
 -- 1.3.6.1.2.1.10.44.1.2.1.7 --  ::= { frMgtVCSigEntry 7 }


frMgtVCSigNetT392 OBJECT-TYPE
        SYNTAX INTEGER (5..30)
        UNITS
               "Seconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Network-
                side T392 polling verification timer value (nT2
                for LMI)  for this UNI/NNI logical port.  If the
                logical port is not performing network-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17],
                LMI [24]"
        DEFVAL { 15 }
 -- 1.3.6.1.2.1.10.44.1.2.1.8 --  ::= { frMgtVCSigEntry 8 }


frMgtVCSigNetnN4 OBJECT-TYPE
        SYNTAX INTEGER (5)
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Network-
                side nN4 maximum status enquires received value
                for this UNI/NNI logical port.  If the logical
                port is not performing network-side procedures or
                is not performing LMI procedures, then this object
                is not instantiated.

                This object applies only to LMI and always has a
                value of 5."
        REFERENCE

               "LMI [24]"
 -- 1.3.6.1.2.1.10.44.1.2.1.9 --  ::= { frMgtVCSigEntry 9 }


frMgtVCSigNetnT3 OBJECT-TYPE
        SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
        UNITS
               "Seconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the Network-
                side nT3 timer (for nN4 status enquires received)
                value for this UNI/NNI logical port.  If the
                logical port is not performing network-side
                procedures or is not performing LMI procedures,
                then this object is not instantiated.

                  This object applies only to LMI."
        REFERENCE

               "LMI [24]"
        DEFVAL { 20 }
 -- 1.3.6.1.2.1.10.44.1.2.1.10 --  ::= { frMgtVCSigEntry 10 }


frMgtVCSigUserLinkRelErrors OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Errors"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of user-side local in-channel
                signaling link reliability errors (i.e., non-
                receipt of Status/Status Enquiry messages or
                invalid sequence numbers in a Link Integrity
                Verification Information Element) for this UNI/NNI
                logical port.  If the logical port is not
                performing user-side procedures, then this object
                is not instantiated."
 -- 1.3.6.1.2.1.10.44.1.2.1.11 --  ::= { frMgtVCSigEntry 11 }


frMgtVCSigUserProtErrors OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Errors"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of user-side local in-channel
                signaling protocol errors (i.e., protocol
                discriminator, unnumbered information, message
                type, call reference, and mandatory information
                element errors) for this UNI/NNI logical port. If
                the logical port is not performing user-side
                procedures, then this object is not instantiated."
 -- 1.3.6.1.2.1.10.44.1.2.1.12 --  ::= { frMgtVCSigEntry 12 }


frMgtVCSigUserChanInactive OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of times the user-side channel was
                declared inactive (i.e., N392 errors in N393
                events) for this UNI/NNI logical port. If the
                logical port is not performing user-side
                procedures, then this object is not instantiated."
 -- 1.3.6.1.2.1.10.44.1.2.1.13 --  ::= { frMgtVCSigEntry 13 }


frMgtVCSigNetLinkRelErrors OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Errors"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of network-side local in-channel
                signaling link reliability errors (i.e., non-
                receipt of Status/Status Enquiry messages or
                invalid sequence numbers in a Link Integrity
                Verification Information Element) for this UNI/NNI
                logical port."
 -- 1.3.6.1.2.1.10.44.1.2.1.14 --  ::= { frMgtVCSigEntry 14 }


frMgtVCSigNetProtErrors OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Errors"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of network-side local in-channel
                signaling protocol errors (i.e., protocol
                discriminator, message type, call reference, and
                mandatory information element errors) for this
                UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.1.2.1.15 --  ::= { frMgtVCSigEntry 15 }


frMgtVCSigNetChanInactive OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Events"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of times the network-side channel was
                declared inactive (i.e., N392 errors in N393
                events) for this UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.1.2.1.16 --  ::= { frMgtVCSigEntry 16 }


frMgtVCSigProcedAdmin OBJECT-TYPE
        SYNTAX INTEGER {
                        u2nnet(1),
                        bidirect(2),
                        u2nuser(3) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the local
                in-channel signaling procedural role that is used
                for this UNI/NNI logical port.  Bidirectional
                procedures implies that both user-side and
                network-side procedural roles are used.

                u2nnet(1)   Logical port operates user to network
                            procedure in the role of the network
                            side

                bidirect(2) Logical port operates the
                            bidirectional procedure (both user
                            and network side roles)

                u2nuser(3)  Logical port operates user to network
                            procedure in the role of the user
                            side"
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
        DEFVAL { u2nnet }
 -- 1.3.6.1.2.1.10.44.1.2.1.17 --  ::= { frMgtVCSigEntry 17 }


frMgtVCSigUserN391Admin OBJECT-TYPE
        SYNTAX INTEGER (1..255)
        UNITS
               "Polls"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                User-side N391 full status polling cycle value for
                this UNI/NNI logical port.  If the logical port is
                not performing user-side (bidirectional)
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
 -- 1.3.6.1.2.1.10.44.1.2.1.18 --  ::= { frMgtVCSigEntry 18 }


frMgtVCSigUserN392Admin OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                User-side N392 error threshold value for this
                UNI/NNI logical port.  If the logical port is not
                performing user-side (bidirectional) procedures,
                then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
 -- 1.3.6.1.2.1.10.44.1.2.1.19 --  ::= { frMgtVCSigEntry 19 }


frMgtVCSigUserN393Admin OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                User-side N393 monitored events count value for
                this UNI/NNI logical port.  If the logical port is
                not performing user-side (bidirectional)
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
 -- 1.3.6.1.2.1.10.44.1.2.1.20 --  ::= { frMgtVCSigEntry 20 }


frMgtVCSigUserT391Admin OBJECT-TYPE
        SYNTAX INTEGER (5..30)
        UNITS
               "Seconds"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                User-side T391 link integrity verification polling
                timer value for this UNI/NNI logical port.  If the
                logical port is not performing user-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17]"
 -- 1.3.6.1.2.1.10.44.1.2.1.21 --  ::= { frMgtVCSigEntry 21 }


frMgtVCSigNetN392Admin OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                Network-side N392 error threshold value (nN2 for
                LMI) for this UNI/NNI logical port.  If the
                logical port is not performing network-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17],
                LMI [24]"
 -- 1.3.6.1.2.1.10.44.1.2.1.22 --  ::= { frMgtVCSigEntry 22 }


frMgtVCSigNetN393Admin OBJECT-TYPE
        SYNTAX INTEGER (1..10)
        UNITS
               "Events"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                Network-side N393 monitored events count value
                (nN3 for LMI) for this UNI/NNI logical port.  If
                the logical port is not performing network-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17],
                LMI [24]"
 -- 1.3.6.1.2.1.10.44.1.2.1.23 --  ::= { frMgtVCSigEntry 23 }


frMgtVCSigNetT392Admin OBJECT-TYPE
        SYNTAX INTEGER (5..30)
        UNITS
               "Seconds"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                Network-side T392 polling verification timer value
                (nT2 for LMI)  for this UNI/NNI logical port. If
                the logical port is not performing network-side
                procedures, then this object is not instantiated."
        REFERENCE

               "Q.933 Annex A [22],
                T1.617 Annex D [17],
                LMI [24]"
 -- 1.3.6.1.2.1.10.44.1.2.1.24 --  ::= { frMgtVCSigEntry 24 }


frMgtVCSigNetnT3Admin OBJECT-TYPE
        SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
        UNITS
               "Seconds"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                Network-side nT3 timer (for nN4 status enquires
                received) value for this UNI/NNI logical port. If
                the logical port is not performing network-side
                procedures or is not performing LMI procedures,
                then this object is not instantiated.  This object
                applies only to LMI."
        REFERENCE

               "LMI [24]"
 -- 1.3.6.1.2.1.10.44.1.2.1.25 --  ::= { frMgtVCSigEntry 25 }


--
-- Frame Relay PVC End-points
--

frPVCEndptTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FrPVCEndptEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The Frame Relay PVC End-Point table.  This table
                is used to model a PVC end-point.  This table
                contains the traffic parameters and statistics for
                a PVC end-point.

                This table is used to identify the traffic
                parameters for a bi-directional PVC segment end-
                point, and it also provides statistics for a PVC
                segment end-point.

                A PVC segment end-point is identified by a UNI/NNI
                logical port index value and DLCI index value.

                If the frame relay service provider allows the
                frame relay CNM subscriber to create, modify or
                delete PVCs using SNMP, then this table is used to
                identify and reserve the requested traffic
                parameters of each PVC segment end-point.  The
                Connection table is used to 'connect' the end-
                points together.  Not all implementations will
                support the capability of
                creating/modifying/deleting PVCs using SNMP as a
                feature of frame relay CNM service.

                Uni-directional PVCs are modeled with zero valued
                traffic parameters in one of the directions (In or
                 Out direction) in this table.

                To create a PVC, the following procedures shall be
                followed:

                1)  Create the entries for the PVC segment
                    endpoints in the frPVCEndptTable by specifying
                    the traffic parameters for the bi-directional
                    PVC segment endpoints. As shown in figure 2, a
                    point-to-point PVC has two endpoints, thus two
                    entries in this table.  Uni-directional PVCs
                    are modeled with zero valued traffic
                    parameters in one direction; all the `In'
                    direction parameters for one frame relay PVC
                    End-point or all the `Out' direction
                    parameters for the other frame relay PVC
                    Endpoint.

                    In    _____________________________  Out
                   >>>>>>|                             |>>>>>>>>
                   ______|    Frame Relay Network      |________
                    Out  |                             |  In
                   <<<<<<|_____________________________|<<<<<<<<
                 Frame Relay                         Frame Relay
                     PVC                                 PVC
                   Endpoint                            Endpoint

                            Figure 2, PVC Terminology

                2)  Go to the Frame Relay Connection Group."
 -- 1.3.6.1.2.1.10.44.1.3 --  ::= { frnetservObjects 3 }


frPVCEndptEntry OBJECT-TYPE
        SYNTAX FrPVCEndptEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry in the Frame Relay PVC Endpoint table."
        INDEX {
                ifIndex,
                frPVCEndptDLCIIndex }
 -- 1.3.6.1.2.1.10.44.1.3.1 --  ::= { frPVCEndptTable 1 }


FrPVCEndptEntry ::= SEQUENCE {
        frPVCEndptDLCIIndex         Integer32,
        frPVCEndptInMaxFrameSize    Integer32,
        frPVCEndptInBc              Integer32,
        frPVCEndptInBe              Integer32,
        frPVCEndptInCIR             Integer32,
        frPVCEndptOutMaxFrameSize   Integer32,
        frPVCEndptOutBc             Integer32,
        frPVCEndptOutBe             Integer32,
        frPVCEndptOutCIR            Integer32,
        frPVCEndptConnectIdentifier Integer32,
        frPVCEndptRowStatus         RowStatus,
        frPVCEndptRcvdSigStatus     INTEGER,
        frPVCEndptInFrames          Counter32,
        frPVCEndptOutFrames         Counter32,
        frPVCEndptInDEFrames        Counter32,
        frPVCEndptInExcessFrames    Counter32,
        frPVCEndptOutExcessFrames   Counter32,
        frPVCEndptInDiscards        Counter32,
        frPVCEndptInOctets          Counter32,
        frPVCEndptOutOctets         Counter32,
        frPVCEndptInDiscardsDESet   Counter32,
        frPVCEndptInFramesFECNSet   Counter32,
        frPVCEndptOutFramesFECNSet  Counter32,
        frPVCEndptInFramesBECNSet   Counter32,
        frPVCEndptOutFramesBECNSet  Counter32,
        frPVCEndptInCongDiscards    Counter32,
        frPVCEndptInDECongDiscards  Counter32,
        frPVCEndptOutCongDiscards   Counter32,
        frPVCEndptOutDECongDiscards Counter32,
        frPVCEndptOutDEFrames       Counter32,
        frPVCEndptAtmIwfConnIndex   Integer32 }


frPVCEndptDLCIIndex OBJECT-TYPE
        SYNTAX Integer32 (16..4194303)
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the DLCI
                value for this PVC end-point.

                The values are restricted to the legal range for
                the size of address field supported by the logical
                port (frLportAddrDLCILen)."
        REFERENCE

               "Q.922 [25]"
 -- 1.3.6.1.2.1.10.44.1.3.1.1 --  ::= { frPVCEndptEntry 1 }


frPVCEndptInMaxFrameSize OBJECT-TYPE
        SYNTAX Integer32 (1..4096)
        UNITS
               "Octets"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is the size in octets of
                the largest frame relay information field for this
                PVC end-point in the ingress direction (into the
                frame relay network).  The value of
                frPVCEndptInMaxFrameSize must be less than or
                equal to the corresponding ifMtu for this frame
                relay UNI/NNI logical port."
        REFERENCE

               "FRF.1 [31]
                Q.922 [25]
                Q.933 [22]"
        DEFVAL { 1600 }
 -- 1.3.6.1.2.1.10.44.1.3.1.2 --  ::= { frPVCEndptEntry 2 }


frPVCEndptInBc OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        UNITS
               "Bits"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the
                committed burst size (Bc) parameter (measured in
                bits) for this PVC end-point in the ingress
                direction (into the frame relay network).

                Note that the max value of this range is lower
                than the max value allowed by Q.933 (16383 *
                10**6).
                Note that the value is encoded in bits whilst the
                Q.933 Link layer core parameters information
                element encodes this information using octet
                units."
        REFERENCE

               "Q.933 [22]"
 -- 1.3.6.1.2.1.10.44.1.3.1.3 --  ::= { frPVCEndptEntry 3 }


frPVCEndptInBe OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        UNITS
               "Bits"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the excess
                burst size (Be) parameter (measured in bits) for
                this PVC end-point in the ingress direction (into
                the frame relay network).

                Note that the max value of this range is lower
                than the max value allowed by Q.933 (16383 *
                10**6).

                Note that the value is encoded in bits whilst the
                Q.933 Link layer core parameters information
                element encodes this information using octet
                units."
        REFERENCE

               "Q.933 [22]"
 -- 1.3.6.1.2.1.10.44.1.3.1.4 --  ::= { frPVCEndptEntry 4 }


frPVCEndptInCIR OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        UNITS
               "Bits per Second"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the
                committed information rate (CIR) parameter
                (measured in bits per second) for this PVC end-
                point in the ingress direction (into the frame
                relay network).

                Note that the max value of this range is lower
                than the max value allowed by Q.933 (2047 *
                10**6)."
        REFERENCE

               "Q.933 [22]"
 -- 1.3.6.1.2.1.10.44.1.3.1.5 --  ::= { frPVCEndptEntry 5 }


frPVCEndptOutMaxFrameSize OBJECT-TYPE
        SYNTAX Integer32 (1..4096)
        UNITS
               "Octets"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is the size in octets of
                the largest frame relay information field for this
                PVC end-point in the egress direction (out of the
                frame relay network).  The value of
                frPVCEndptOutMaxFrameSize must be less than or
                equal to the corresponding ifMtu for this frame
                relay UNI/NNI logical port."
        REFERENCE

               "FRF.1 [31]
                Q.922 [25]
                Q.933 [22]"
        DEFVAL { 1600 }
 -- 1.3.6.1.2.1.10.44.1.3.1.6 --  ::= { frPVCEndptEntry 6 }


frPVCEndptOutBc OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        UNITS
               "Bits"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the
                committed burst size (Bc) parameter (measured in
                bits) for this PVC end-point in the egress
                direction (out of the frame relay network).

                Note that the max value of this range is lower
                than the max value allowed by Q.933 (16383 *
                10**6).

                Note that the value is encoded in bits whilst the
                Q.933 Link layer core parameters information
                element encodes this information using octet
                units."
        REFERENCE

               "Q.933 [22]"
 -- 1.3.6.1.2.1.10.44.1.3.1.7 --  ::= { frPVCEndptEntry 7 }


frPVCEndptOutBe OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        UNITS
               "Bits"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the excess
                burst size (Be) parameter (measured in bits) for
                this PVC end-point in the egress direction (out of
                the frame relay network).

                Note that the max value of this range is lower
                than the max value allowed by Q.933 (16383 *
                10**6).

                Note that the value is encoded in bits whilst the
                Q.933 Link layer core parameters information
                element encodes this information using octet
                units."
        REFERENCE

               "Q.933 [22]"
 -- 1.3.6.1.2.1.10.44.1.3.1.8 --  ::= { frPVCEndptEntry 8 }


frPVCEndptOutCIR OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        UNITS
               "Bits per Second"
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the
                committed information rate (CIR) parameter
                (measured in bits per second) for this PVC end-
                point in the egress direction (out of the frame
                relay network).

                Note that the max value of this range is lower
                than the max value allowed by Q.933 (2047 *
                10**6)."
        REFERENCE

               "Q.933 [22]"
 -- 1.3.6.1.2.1.10.44.1.3.1.9 --  ::= { frPVCEndptEntry 9 }


frPVCEndptConnectIdentifier OBJECT-TYPE
        SYNTAX Integer32 (0..2147483647)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "This object is used to associate PVC end-points
                as being part of one PVC segment connection. This
                value of this object is equal to the value of
                frPVCConnectIndex, which is used as one of the
                indices into the frPVCConnectTable.

                A connection that has been cross-connected via the
                FR/ATM PVC Service IWF cross-connect table will
                return the value zero when this object is read. In
                case of these interworked connections, the
                frPVCEndptAtmIwfConnIndex object must be accessed
                to select the entry in the FR/ATM PVC Service IWF
                cross-connect table.

                The value of this object is provided by the agent,
                after the associated entries in the
                frPVCConnectTable or frAtmIwfConnectionTable have
                been created."
 -- 1.3.6.1.2.1.10.44.1.3.1.10 --  ::= { frPVCEndptEntry 10 }


frPVCEndptRowStatus OBJECT-TYPE
        SYNTAX RowStatus
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "This object is used to create new rows in this
                table, modify existing rows, and to delete
                existing rows.  To create a new PVC, the entries
                for the PVC segment end-points in the
                frPVCEndptTable must first be created.  Next, the
                frPVCConnectTable is used to associate the frame
                relay PVC segment end-points.  In order for the
                manager to have the necessary error diagnostics,
                the frPVCEndptRowStatus object must initially be
                set to `createAndWait(5)'.  While the
                frPVCEndptRowStatus object is in the
                `createAndWait(5)' state, the manager can set each
                columnar object and get the necessary error
                diagnostics.  The frPVCEndptRowStatus object may
                not be set to `active(1)' unless the following
                columnar objects exist in this row:
                frPVCEndptInMaxFrameSize, frPVCEndptInBc,
                frPVCEndptInBe, frPVCEndptInCIR,
                frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,
                frPVCEndptOutBe, and frPVCEndptOutCIR."
 -- 1.3.6.1.2.1.10.44.1.3.1.11 --  ::= { frPVCEndptEntry 11 }


frPVCEndptRcvdSigStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        deleted(1),
                        active(2),
                        inactive(3),
                        none(4) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the PVC
                status received via the local in-channel signaling
                procedures for this PVC end-point.  This object is
                only pertinent for interfaces that perform the
                bidirectional procedures.

                Each value has the following meaning:
                  deleted(1):  This PVC is not listed in the full
                               status reports received from the
                               user device.  The object retains
                               this value for as long as the PVC
                               is not listed in the full status
                               reports

                active(2):   This PVC is reported as active, or
                               operational, by the user device.

                  inactive(3): This PVC is reported as inactive,
                               or non-operational, by the user
                               device.

                  none(4):     This interface is only using the
                               network-side in-channel signaling
                               procedures, so this object does
                               not apply."
 -- 1.3.6.1.2.1.10.44.1.3.1.12 --  ::= { frPVCEndptEntry 12 }


frPVCEndptInFrames OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) for this PVC end-point. This includes
                any frames discarded by the network due to
                submitting more than Bc + Be data or due to any
                network congestion recovery procedures."
 -- 1.3.6.1.2.1.10.44.1.3.1.13 --  ::= { frPVCEndptEntry 13 }


frPVCEndptOutFrames OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames sent by the network (egress)
                regardless of whether they are Bc or Be frames for
                this PVC end-point."
 -- 1.3.6.1.2.1.10.44.1.3.1.14 --  ::= { frPVCEndptEntry 14 }


frPVCEndptInDEFrames OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) with the DE bit set to (1) for this PVC
                end-point."
 -- 1.3.6.1.2.1.10.44.1.3.1.15 --  ::= { frPVCEndptEntry 15 }


frPVCEndptInExcessFrames OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) for this PVC end-point which were
                treated as excess traffic.  Frames which are sent
                to the network with DE set to zero are treated as
                excess when more than Bc bits are submitted to the
                network during the Committed Information Rate
                Measurement Interval (Tc).  Excess traffic may or
                may not be discarded at the ingress if more than
                Bc + Be bits are submitted to the network during
                Tc.  Traffic discarded at the ingress is not
                recorded in frPVCEndptInExcessFrames.  Frames
                which are sent to the network with DE set to one
                are also treated as excess traffic."
 -- 1.3.6.1.2.1.10.44.1.3.1.16 --  ::= { frPVCEndptEntry 16 }


frPVCEndptOutExcessFrames OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames sent by the network (egress)
                for this PVC end-point which were treated as
                excess traffic.  (The DE bit may be set to one.)"
 -- 1.3.6.1.2.1.10.44.1.3.1.17 --  ::= { frPVCEndptEntry 17 }


frPVCEndptInDiscards OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) that were discarded due to traffic
                enforcement for this PVC end-point.  Congestion
                discards are not counted in this object."
 -- 1.3.6.1.2.1.10.44.1.3.1.18 --  ::= { frPVCEndptEntry 18 }


frPVCEndptInOctets OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Octets"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of octets received by the network
                (ingress) for this PVC end-point.  This counter
                should only count octets from the beginning of the
                frame relay header field to the end of user data.
                If the network supporting frame relay can not
                count octets, then this count should be an
                approximation."
 -- 1.3.6.1.2.1.10.44.1.3.1.19 --  ::= { frPVCEndptEntry 19 }


frPVCEndptOutOctets OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Octets"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of octets sent by the network (egress)
                for this PVC end-point.  This counter should only
                count octets from the beginning of the frame relay
                header field to the end of user data.  If the
                network supporting frame relay can not count
                octets, then this count should be an
                approximation."
 -- 1.3.6.1.2.1.10.44.1.3.1.20 --  ::= { frPVCEndptEntry 20 }


frPVCEndptInDiscardsDESet OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) that were discarded with the DE bit set
                due to traffic enforcement for this PVC end-point.
                Congestion discards are not counted in this
                object."
 -- 1.3.6.1.2.1.10.44.1.3.1.21 --  ::= { frPVCEndptEntry 21 }


frPVCEndptInFramesFECNSet OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) that have the FECN bit set for this PVC
                end-point."
 -- 1.3.6.1.2.1.10.44.1.3.1.22 --  ::= { frPVCEndptEntry 22 }


frPVCEndptOutFramesFECNSet OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames sent by the network (egress)
                that have the FECN bit set for this PVC end-
                point."
 -- 1.3.6.1.2.1.10.44.1.3.1.23 --  ::= { frPVCEndptEntry 23 }


frPVCEndptInFramesBECNSet OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) that have the BECN bit set for this PVC
                end-point."
 -- 1.3.6.1.2.1.10.44.1.3.1.24 --  ::= { frPVCEndptEntry 24 }


frPVCEndptOutFramesBECNSet OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames sent by the network (egress)
                that have the BECN bit set for this PVC end-
                point."
 -- 1.3.6.1.2.1.10.44.1.3.1.25 --  ::= { frPVCEndptEntry 25 }


frPVCEndptInCongDiscards OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames received by the network
                (ingress) that were discarded due to input buffer
                congestion, rather than traffic enforcement, for
                this PVC end-point."
 -- 1.3.6.1.2.1.10.44.1.3.1.26 --  ::= { frPVCEndptEntry 26 }


frPVCEndptInDECongDiscards OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames counted by
                frPVCEndptInCongDiscards with the DE bit set to
                (1)."
 -- 1.3.6.1.2.1.10.44.1.3.1.27 --  ::= { frPVCEndptEntry 27 }


frPVCEndptOutCongDiscards OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames sent by the network (egress)
                that were discarded due to output buffer
                congestion for this PVC end-point."
 -- 1.3.6.1.2.1.10.44.1.3.1.28 --  ::= { frPVCEndptEntry 28 }


frPVCEndptOutDECongDiscards OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames counted by
                frPVCEndptOutCongDiscards with the DE bit set to
                (1)."
 -- 1.3.6.1.2.1.10.44.1.3.1.29 --  ::= { frPVCEndptEntry 29 }


frPVCEndptOutDEFrames OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Frames"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of frames sent by the network (egress)
                with the DE bit set to (1) for this PVC end-
                point."
 -- 1.3.6.1.2.1.10.44.1.3.1.30 --  ::= { frPVCEndptEntry 30 }


frPVCEndptAtmIwfConnIndex OBJECT-TYPE
        SYNTAX Integer32 (0..2147483647)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "This object contains the index value of the
                FR/ATM cross-connect table entry used to link the
                frame relay PVC with an ATM PVC.

                Each row of the frPVCEndptTable that is not
                cross-connected with an ATM PVC must return the
                value zero when this object is read.

                The value of this object is initialized by the
                agent after the associated entries in the
                frAtmIwfConnectionTable have been created.

                The value of this object is reset to zero
                following destruction of the associated entry in
                the frAtmIwfConnectionTable"
 -- 1.3.6.1.2.1.10.44.1.3.1.31 --  ::= { frPVCEndptEntry 31 }


--
-- Frame Relay PVC Connections
--

frPVCConnectIndexValue OBJECT-TYPE
        SYNTAX INTEGER (0..2147483647)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "This object returns a hint to be used for
                frPVCConnectIndex when creating entries in the
                frPVCConnectTable.

                The value 0 indicates that no unassigned entries
                are available.

                To obtain the frPVCConnectIndex value for a new
                entry, the manager issues a management protocol
                retrieval operation to obtain the current value of
                this object.  After each retrieval, the agent must
                modify the value to the next unassigned index to
                prevent assignment of the same value to multiple
                management systems.

                A management system should repeat the read to
                obtain a new value should an attempt to create the
                new row using the previously returned hint fail."
 -- 1.3.6.1.2.1.10.44.1.4 --  ::= { frnetservObjects 4 }


frPVCConnectTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FrPVCConnectEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The Frame Relay PVC Connect Table is used to
                model the bi-directional PVC segment flows
                including:  point-to-point PVCs, point-to-
                multipoint PVCs, and multipoint-to-multipoint
                PVCs.

                This table has read-create access and is used to
                associate PVC end-points together as belonging to
                one connection.  The frPVCConnectIndex is used to
                associate all the bi-directional flows.  Not all
                implementations will support the capability of
                creating/modifying/deleting PVCs using SNMP as a
                feature of frame relay CNM service.

                Once the entries in the frPVCEndptTable are
                created, the following step are used to associate
                the PVC end-points as belonging to one PVC
                connection:

                1)  Obtain a unique frPVCConnectIndex
                    using the frPVCConnectIndexValue object.

                2)  Connect the PVC segment endpoints together
                    with the applicable frPVCConnectIndex value
                    obtained via  frPVCConnectIndexValue.  The
                    entries in this table are created by using
                    the frPVCConnectRowStatus object.

                3)  The agent will provide the value of the
                    corresponding instances of
                    frPVCEndptConnectIdentifier with the
                    frPVCConnectIndex value.

                4)  Set frPVCConnectAdminStatus to `active(1)' in
                    all rows for this PVC segment to turn the
                    PVC on.

                For example, the Frame Relay PVC Connection Group
                models a bi-directional, point-to-point PVC
                segment as one entry in this table.

                Frame Relay                           Frame Relay
                 Network                                 Network
                 Low Port                               High Port
                         __________________________________
                        |                                  |
                   _____| >> from low to high PVC flow  >> |_____
                        | << from high to low PVC flow  << |
                        |__________________________________|

                The terms low and high are chosen to represent
                numerical ordering of a PVC segment's endpoints
                for representation in this table.  That is, the
                endpoint with the lower value of ifIndex is termed
                'low', while the opposite endpoint of the segment
                is termed 'high'.  This terminology is to provide
                directional information; for example the
                frPVCConnectL2hOperStatus and
                frPVCConnectH2lOperStatus as illustrated above.

                If the Frame Relay Connection table is used to
                model a unidirectional PVC, then one direction
                (either from low to high or from high to low) has
                 its Operational Status equal to down.

                 A PVC segment is a portion of a PVC that traverses
                one Frame Relay Network, and a PVC segment is
                identified by its two end-points (UNI/NNI logical
                port index value and DLCI index value) through one
                Frame Relay Network."
 -- 1.3.6.1.2.1.10.44.1.5 --  ::= { frnetservObjects 5 }


frPVCConnectEntry OBJECT-TYPE
        SYNTAX FrPVCConnectEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry in the Frame Relay PVC Connect table.
                This entry is used to model a PVC segment in two
                directions."
        INDEX {
                frPVCConnectIndex,
                frPVCConnectLowIfIndex,
                frPVCConnectLowDLCIIndex,
                frPVCConnectHighIfIndex,
                frPVCConnectHighDLCIIndex }
 -- 1.3.6.1.2.1.10.44.1.5.1 --  ::= { frPVCConnectTable 1 }


FrPVCConnectEntry ::= SEQUENCE {
        frPVCConnectIndex         Integer32,
        frPVCConnectLowIfIndex    InterfaceIndex,
        frPVCConnectLowDLCIIndex  Integer32,
        frPVCConnectHighIfIndex   InterfaceIndex,
        frPVCConnectHighDLCIIndex Integer32,
        frPVCConnectAdminStatus   INTEGER,
        frPVCConnectL2hOperStatus INTEGER,
        frPVCConnectH2lOperStatus INTEGER,
        frPVCConnectL2hLastChange TimeStamp,
        frPVCConnectH2lLastChange TimeStamp,
        frPVCConnectRowStatus     RowStatus,
        frPVCConnectUserName      SnmpAdminString,
        frPVCConnectProviderName  SnmpAdminString }


frPVCConnectIndex OBJECT-TYPE
        SYNTAX Integer32 (0..2147483647)
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the
                frPVCConnectIndexValue obtained to uniquely
                identify this PVC segment connection."
 -- 1.3.6.1.2.1.10.44.1.5.1.1 --  ::= { frPVCConnectEntry 1 }


frPVCConnectLowIfIndex OBJECT-TYPE
        SYNTAX InterfaceIndex
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to IF-MIB
                ifIndex value of the UNI/NNI logical port for this
                PVC segment.  The term low implies that this PVC
                segment end-point has the numerically lower
                ifIndex value than the connected/associated PVC
                segment end-point.

                RFC 1604 permitted a zero value for this object to
                identify termination at a non-frame relay
                interface.  However, this cross-connect table is
                limited to frame relay connections.  See the frame
                relay/ATM IWF MIB [28] for the cross-connect table
                used for those types of connections."
 -- 1.3.6.1.2.1.10.44.1.5.1.2 --  ::= { frPVCConnectEntry 2 }


frPVCConnectLowDLCIIndex OBJECT-TYPE
        SYNTAX Integer32 (16..4194303)
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the DLCI
                value for this end-point of the PVC segment."
        REFERENCE

               "Q.922 [25]"
 -- 1.3.6.1.2.1.10.44.1.5.1.3 --  ::= { frPVCConnectEntry 3 }


frPVCConnectHighIfIndex OBJECT-TYPE
        SYNTAX InterfaceIndex
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to IF-MIB
                ifIndex value for the UNI/NNI logical port for
                this PVC segment.  The term high implies that this
                PVC segment end-point has the numerically higher
                ifIndex value than the connected/associated PVC
                segment end-point."
 -- 1.3.6.1.2.1.10.44.1.5.1.4 --  ::= { frPVCConnectEntry 4 }


frPVCConnectHighDLCIIndex OBJECT-TYPE
        SYNTAX Integer32 (16..4194303)
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the egress
                DLCI value for this end-point of the PVC segment."
        REFERENCE

               "Q.922 [25]"
 -- 1.3.6.1.2.1.10.44.1.5.1.5 --  ::= { frPVCConnectEntry 5 }


frPVCConnectAdminStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        active(1),
                        inactive(2),
                        testing(3) }
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The value of this object identifies the desired
                administrative status of this bi-directional PVC
                segment.  The active(1) state means the PVC
                segment is currently operational; the inactive(2)
                state means the PVC segment is currently not
                operational; the testing(3) state means the PVC
                segment is currently undergoing a test.  This
                state is set by an administrative entity.  This
                value affects the PVC status indicated across the
                ingress NNI/UNI of both end-points of the bi-
                directional PVC segment.  When a PVC segment
                connection is created using this table, this
                object is initially set to `inactive(2)'.  After
                the frPVCConnectRowStatus object is set to
                `active(1)' (and the corresponding/associated
                entries in the frPVCEndptTable have their
                frPVCEndptRowStatus object set to `active(1)'),
                the frPVCConnectAdminStatus object may be set to
                `active(1)' to turn on the PVC segment
                connection."
 -- 1.3.6.1.2.1.10.44.1.5.1.6 --  ::= { frPVCConnectEntry 6 }


frPVCConnectL2hOperStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        active(1),
                        inactive(2),
                        testing(3),
                        unknown(4) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the current
                operational status of the PVC segment connection
                in one direction; (i.e., in the low to high
                direction). This value affects the PVC status
                indicated across the ingress NNI/UNI (low side) of
                the PVC segment.

                The values mean:

                active(1)   - PVC is currently operational

                inactive(2) - PVC is currently not operational.
                              This may be because of an underlying
                              LMI or DS1 failure.

                testing(3)  - PVC is currently undergoing a test.
                              This may be because of an underlying
                              frLport or DS1 undergoing a test.

                unknown(4)  - the status of the PVC currently can
                              not be determined."
 -- 1.3.6.1.2.1.10.44.1.5.1.7 --  ::= { frPVCConnectEntry 7 }


frPVCConnectH2lOperStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        active(1),
                        inactive(2),
                        testing(3),
                        unknown(4) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object identifies the current
                operational status of the PVC segment connection
                in one direction; (i.e., in the high to low
                direction)..  This value affects the PVC status
                indicated across the ingress NNI/UNI (high side)
                of the PVC segment.

                The values mean:

                active(1)   - PVC is currently operational

                inactive(2) - PVC is currently not operational.
                              This may be because of an underlying
                              LMI or DS1 failure.

                testing(3)  - PVC is currently undergoing a test.
                              This may be because of an underlying
                              frLport or DS1 undergoing a test.

                unknown(4)  - the status of the PVC currently can
                              not be determined."
 -- 1.3.6.1.2.1.10.44.1.5.1.8 --  ::= { frPVCConnectEntry 8 }


frPVCConnectL2hLastChange OBJECT-TYPE
        SYNTAX TimeStamp
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of the Interface MIB's sysUpTime object
                at the time this PVC segment entered its current
                operational state in the low to high direction.
                If the current state was entered prior to the last
                re-initialization of the FRS agent, then this
                object contains a zero value."
 -- 1.3.6.1.2.1.10.44.1.5.1.9 --  ::= { frPVCConnectEntry 9 }


frPVCConnectH2lLastChange OBJECT-TYPE
        SYNTAX TimeStamp
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of the Interface MIB's sysUpTime object
                at the time this PVC segment entered its current
                operational state in the high to low direction.
                If the current state was entered prior to the last
                re-initialization of the FRS agent, then this
                object contains a zero value."
 -- 1.3.6.1.2.1.10.44.1.5.1.10 --  ::= { frPVCConnectEntry 10 }


frPVCConnectRowStatus OBJECT-TYPE
        SYNTAX RowStatus
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "The status of this entry in the
                frPVCConnectTable.  This variable is used to
                create new connections for the PVC end-points and
                to change existing connections of the PVC end-
                points.  This object must be initially set to
                `createAndWait(5)'. In this state, the agent
                checks the parameters in the associated entries in
                the frPVCEndptTable to verify that the PVC end-
                points can be connected (i.e., the In parameters
                for one PVC end-point are equal to the Out
                parameters for the other PVC end-point).  This
                object can not be set to `active(1)' unless the
                following columnar object exists in this row:
                frPVCConnectAdminStatus.  The agent also supplies
                the associated value of frPVCConnectIndex for the
                frPVCEndptConnectIdentifier instances.  To turn on
                a PVC segment connection, the
                frPVCConnectAdminStatus is set to `active(1)'."
 -- 1.3.6.1.2.1.10.44.1.5.1.11 --  ::= { frPVCConnectEntry 11 }


frPVCConnectUserName OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "This is a service user assigned textual
                representation of a PVC."
 -- 1.3.6.1.2.1.10.44.1.5.1.12 --  ::= { frPVCConnectEntry 12 }


frPVCConnectProviderName OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
               "This is a system supplied textual representation
                of PVC.  It is assigned by the service provider."
 -- 1.3.6.1.2.1.10.44.1.5.1.13 --  ::= { frPVCConnectEntry 13 }


--
-- The Frame Relay Accounting
--

frAccountPVCTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FrAccountPVCEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The Frame Relay Accounting PVC table.  This table
                is used to perform accounting on a PVC segment
                end-point basis."
 -- 1.3.6.1.2.1.10.44.1.6 --  ::= { frnetservObjects 6 }


frAccountPVCEntry OBJECT-TYPE
        SYNTAX FrAccountPVCEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry in the Frame Relay Accounting PVC
                table."
        INDEX {
                ifIndex,
                frAccountPVCDLCIIndex }
 -- 1.3.6.1.2.1.10.44.1.6.1 --  ::= { frAccountPVCTable 1 }


FrAccountPVCEntry ::= SEQUENCE {
        frAccountPVCDLCIIndex   Integer32,
        frAccountPVCSegmentSize Integer32,
        frAccountPVCInSegments  Counter32,
        frAccountPVCOutSegments Counter32 }


frAccountPVCDLCIIndex OBJECT-TYPE
        SYNTAX Integer32 (16..4194303)
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the DLCI
                value for this PVC segment end-point."
        REFERENCE

               "Q.922 [25]"
 -- 1.3.6.1.2.1.10.44.1.6.1.1 --  ::= { frAccountPVCEntry 1 }


frAccountPVCSegmentSize OBJECT-TYPE
        SYNTAX Integer32
        UNITS
               "Octets"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the Segment
                Size for this PVC segment end-point."
 -- 1.3.6.1.2.1.10.44.1.6.1.2 --  ::= { frAccountPVCEntry 2 }


frAccountPVCInSegments OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Segments"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the number
                of segments received by this PVC segment end-
                point."
 -- 1.3.6.1.2.1.10.44.1.6.1.3 --  ::= { frAccountPVCEntry 3 }


frAccountPVCOutSegments OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Segments"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the number
                of segments sent by this PVC segment end-point."
 -- 1.3.6.1.2.1.10.44.1.6.1.4 --  ::= { frAccountPVCEntry 4 }


--
-- Accounting on a Frame Relay Logical Port
--

frAccountLportTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FrAccountLportEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The Frame Relay Accounting Logical Port table.
                This table is used to perform accounting on a
                UNI/NNI Logical Port basis."
 -- 1.3.6.1.2.1.10.44.1.7 --  ::= { frnetservObjects 7 }


frAccountLportEntry OBJECT-TYPE
        SYNTAX FrAccountLportEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry in the Frame Relay Accounting Logical
                Port table."
        INDEX {
                ifIndex }
 -- 1.3.6.1.2.1.10.44.1.7.1 --  ::= { frAccountLportTable 1 }


FrAccountLportEntry ::= SEQUENCE {
        frAccountLportSegmentSize Integer32,
        frAccountLportInSegments  Counter32,
        frAccountLportOutSegments Counter32 }


frAccountLportSegmentSize OBJECT-TYPE
        SYNTAX Integer32
        UNITS
               "Octets"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the Segment
                Size for this UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.1.7.1.1 --  ::= { frAccountLportEntry 1 }


frAccountLportInSegments OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Segments"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the number
                of segments received by this UNI/NNI logical
                port."
 -- 1.3.6.1.2.1.10.44.1.7.1.2 --  ::= { frAccountLportEntry 2 }


frAccountLportOutSegments OBJECT-TYPE
        SYNTAX Counter32
        UNITS
               "Segments"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of this object is equal to the number
                of segments sent by this UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.1.7.1.3 --  ::= { frAccountLportEntry 3 }



--
-- Frame Relay Network Service Notifications
--

frPVCConnectStatusChange NOTIFICATION-TYPE
        OBJECTS {
                frPVCConnectIndex,
                frPVCConnectLowIfIndex,
                frPVCConnectLowDLCIIndex,
                frPVCConnectHighIfIndex,
                frPVCConnectHighDLCIIndex,
                frPVCConnectL2hOperStatus,
                frPVCConnectH2lOperStatus,
                frPVCEndptRcvdSigStatus}
        STATUS deprecated
        DESCRIPTION
               "Refer to the description of the
                frPVCConnectStatusNotif notification that has
                replaced this notification.  The notification is
                deprecated due to the incorrect inclusion of index
                values and to take advantage of the trap prefix
                for automatic conversion from SMIv2 to SMIv1 by
                making the one but last sub-ID a zero (i.e. the
                so-called trap prefix)."
 -- 1.3.6.1.2.1.10.44.2.1 --  ::= { frnetservTraps 1 }


frPVCConnectStatusNotif NOTIFICATION-TYPE
        OBJECTS {
                frPVCConnectL2hOperStatus,
                frPVCConnectH2lOperStatus,
                frPVCEndptRcvdSigStatus}
        STATUS current
        DESCRIPTION
               "This notification indicates that the indicated
                PVC has changed state.

                This notification is not sent if an FR-UNI changes
                state; a linkDown or linkUp notification should be
                sent instead.  The first instance of
                frPVCEndptRcvdSigStatus is for the endpoint with
                LowIfIndex, LowDLCIIndex.  The second instance of
                frPVCEndptRcvdSigStatus is for the endpoint with
                HighIfIndex, HighDLCIIndex"
 -- 1.3.6.1.2.1.10.44.2.0.2 --  ::= { frnetservTrapsPrefix 2 }

-- Conformance Information

frnetservConformance OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.10.44.3 --  ::= { frnetservMIB 3 }

frnetservGroups OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.10.44.3.1 --  ::= { frnetservConformance 1 }

frnetservCompliances OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.10.44.3.2 --  ::= { frnetservConformance 2 }


--
--  Service (Read-only) Modules
--

frnetservCompliance2 MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION
               "The compliance statement for SNMP entities which
                have Frame Relay Network Service Interfaces.

                The distinction between 'service' and 'switch' is
                that a 'switch' is configured via this MIB.
                Hence, the various read/write objects have write
                capability.  A 'service' represents a passive
                monitor-only customer network management
                interface.  The various read/write objects are
                restricted to read-only capability."

        MODULE 
        MANDATORY-GROUPS {
                        frnetservLportGroup2,
                        frnetservMgtVCSigGroup,
                        frnetservPVCEndptGroup,
                        frnetservPVCEndptGroup2,
                        frnetservPVCConnectGroup,
                        frnetservPVCConnectNamesGroup,
                        frnetservPVCNotifGroup2 }

        GROUP frnetservAccountPVCGroup
          DESCRIPTION
               "This group is optional for frame relay
                interfaces.  It is mandatory if and only if
                accounting is performed on a PVC basis this frame
                relay interface."
        GROUP frnetservAccountLportGroup
          DESCRIPTION
               "This group is optional for frame relay
                interfaces.  It is mandatory if and only if
                accounting is performed on a logical port basis
                this frame relay interface."
        OBJECT frPVCEndptInMaxFrameSize
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptInBc
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptInBe
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptInCIR
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutMaxFrameSize
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutBc
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutBe
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutCIR
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptRowStatus
          SYNTAX INTEGER {
                        active(1) }
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required, and only one of the
                six enumerated values for the RowStatus textual
                convention need be supported, specifically:
                active(1)."
        OBJECT frPVCConnectAdminStatus
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCConnectRowStatus
          SYNTAX INTEGER {
                        active(1) }
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required, and only one of the
                six enumerated values for the RowStatus textual
                convention need be supported, specifically:
                active(1)."
        OBJECT frLportFragControl
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frLportFragSize
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCConnectUserName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCConnectProviderName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
 -- 1.3.6.1.2.1.10.44.3.2.2 --  ::= { frnetservCompliances 2 }


--
-- Switch (Configuration) Compliance
--

frnetSwitchCompliance MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION
               "The compliance statement for SNMP entities which
                have Frame Relay Network Switch objects.

                The distinction between 'service' and 'switch' is
                that a 'switch' is configured via this MIB.
                Hence, the various read/write objects have write
                capability.  A 'service' represents a passive
                monitor-only customer network management
                interface.  The various read/write objects are
                restricted to read-only capability."

        MODULE 
        MANDATORY-GROUPS {
                        frnetservLportGroup2,
                        frnetservLportAdminGroup,
                        frnetservMgtVCSigGroup,
                        frnetservMgtVCSigAdminGroup,
                        frnetservPVCEndptGroup,
                        frnetservPVCEndptGroup2,
                        frnetservPVCConnectGroup,
                        frnetservPVCConnectNamesGroup,
                        frnetservPVCNotifGroup2 }

        GROUP frnetservAccountPVCGroup
          DESCRIPTION
               "This group is optional for frame relay
                interfaces.  It is mandatory if and only if
                accounting is performed on a PVC basis this frame
                relay interface."
        GROUP frnetservAccountLportGroup
          DESCRIPTION
               "This group is optional for frame relay
                interfaces.  It is mandatory if and only if
                accounting is performed on a logical port basis
                this frame relay interface."
 -- 1.3.6.1.2.1.10.44.3.2.3 --  ::= { frnetservCompliances 3 }


--
-- Historical RFC 1604 Compliance Modules
--

frnetservCompliance MODULE-COMPLIANCE
        STATUS deprecated
        DESCRIPTION
               "The compliance statement for SNMP entities which
                have Frame Relay Network Service Interfaces.

                This compliance statement has been deprecated in
                favor of frnetservCompliance2.  The new compliance
                module expands the mandatory groups to include
                notification and other new objects."

        MODULE 
        MANDATORY-GROUPS {
                        frnetservLportGroup,
                        frnetservMgtVCSigGroup,
                        frnetservPVCEndptGroup,
                        frnetservPVCConnectGroup }

        GROUP frnetservAccountPVCGroup
          DESCRIPTION
               "This group is optional for Frame Relay
                interfaces.  It is mandatory if and only if
                accounting is performed on a PVC basis this Frame
                Relay interface."
        GROUP frnetservAccountLportGroup
          DESCRIPTION
               "This group is optional for Frame Relay
                interfaces.  It is mandatory if and only if
                accounting is performed on a logical port basis
                this Frame Relay interface."
        OBJECT frPVCEndptInMaxFrameSize
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptInBc
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptInBe
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptInCIR
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutMaxFrameSize
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutBc
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutBe
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptOutCIR
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCEndptRowStatus
          SYNTAX INTEGER {
                        active(1) }
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required, and only one of the
                six enumerated values for the RowStatus textual
                convention need be supported, specifically:
                active(1)."
        OBJECT frPVCConnectAdminStatus
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT frPVCConnectRowStatus
          SYNTAX INTEGER {
                        active(1) }
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required, and only one of the
                six enumerated values for the RowStatus textual
                convention need be supported, specifically:
                active(1)."
 -- 1.3.6.1.2.1.10.44.3.2.1 --  ::= { frnetservCompliances 1 }

--
-- Frame Relay Service MIB Object Groups
--

frnetservLportGroup OBJECT-GROUP
        OBJECTS {
                frLportNumPlan,
                frLportContact,
                frLportLocation,
                frLportType,
                frLportAddrDLCILen,
                frLportVCSigProtocol,
                frLportVCSigPointer }
        STATUS deprecated
        DESCRIPTION
               "A collection of objects providing information
                applicable to a Frame Relay Logical Port.  This
                group has been deprecated to eliminate reference
                to the object frLportVCSigPointer.

                Use the new group frnetservLportGroup2 as a
                replacement for this group."
 -- 1.3.6.1.2.1.10.44.3.1.1 --  ::= { frnetservGroups 1 }

frnetservMgtVCSigGroup OBJECT-GROUP
        OBJECTS {
                frMgtVCSigProced,
                frMgtVCSigUserN391,
                frMgtVCSigUserN392,
                frMgtVCSigUserN393,
                frMgtVCSigUserT391,
                frMgtVCSigNetN392,
                frMgtVCSigNetN393,
                frMgtVCSigNetT392,
                frMgtVCSigNetnN4,
                frMgtVCSigNetnT3,
                frMgtVCSigUserLinkRelErrors,
                frMgtVCSigUserProtErrors,
                frMgtVCSigUserChanInactive,
                frMgtVCSigNetLinkRelErrors,
                frMgtVCSigNetProtErrors,
                frMgtVCSigNetChanInactive }
        STATUS current
        DESCRIPTION
               "A collection of objects providing information
                applicable to the Local In-Channel Signaling
                Procedures used for a UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.3.1.2 --  ::= { frnetservGroups 2 }

frnetservPVCEndptGroup OBJECT-GROUP
        OBJECTS {
                frPVCConnectIndexValue,
                frPVCEndptInMaxFrameSize,
                frPVCEndptInBc,
                frPVCEndptInBe,
                frPVCEndptInCIR,
                frPVCEndptOutMaxFrameSize,
                frPVCEndptOutBc,
                frPVCEndptOutBe,
                frPVCEndptOutCIR,
                frPVCEndptConnectIdentifier,
                frPVCEndptRowStatus,
                frPVCEndptRcvdSigStatus,
                frPVCEndptInFrames,
                frPVCEndptOutFrames,
                frPVCEndptInDEFrames,
                frPVCEndptInExcessFrames,
                frPVCEndptOutExcessFrames,
                frPVCEndptInDiscards,
                frPVCEndptInOctets,
                frPVCEndptOutOctets }
        STATUS current
        DESCRIPTION
               "A collection of objects providing information
                applicable to a Frame Relay PVC end-point."
 -- 1.3.6.1.2.1.10.44.3.1.3 --  ::= { frnetservGroups 3 }

frnetservPVCConnectGroup OBJECT-GROUP
        OBJECTS {
                frPVCConnectAdminStatus,
                frPVCConnectL2hOperStatus,
                frPVCConnectH2lOperStatus,
                frPVCConnectL2hLastChange,
                frPVCConnectH2lLastChange,
                frPVCConnectRowStatus }
        STATUS current
        DESCRIPTION
               "A collection of objects providing information
                applicable to a Frame Relay PVC connection."
 -- 1.3.6.1.2.1.10.44.3.1.4 --  ::= { frnetservGroups 4 }

frnetservAccountPVCGroup OBJECT-GROUP
        OBJECTS {
                frAccountPVCSegmentSize,
                frAccountPVCInSegments,
                frAccountPVCOutSegments }
        STATUS current
        DESCRIPTION
               "A collection of objects providing accounting
                information application to a Frame Relay PVC end-
                point."
 -- 1.3.6.1.2.1.10.44.3.1.5 --  ::= { frnetservGroups 5 }

frnetservAccountLportGroup OBJECT-GROUP
        OBJECTS {
                frAccountLportSegmentSize,
                frAccountLportInSegments,
                frAccountLportOutSegments }
        STATUS current
        DESCRIPTION
               "A collection of objects providing accounting
                information application to a Frame Relay logical
                port."
 -- 1.3.6.1.2.1.10.44.3.1.6 --  ::= { frnetservGroups 6 }

frnetservLportGroup2 OBJECT-GROUP
        OBJECTS {
                frLportNumPlan,
                frLportContact,
                frLportLocation,
                frLportType,
                frLportAddrDLCILen,
                frLportVCSigProtocol,
                frLportFragControl,
                frLportFragSize }
        STATUS current
        DESCRIPTION
               "A collection of objects providing information
                applicable to a Frame Relay Logical Port.

                This new version of the Logical Port Group
                eliminates the frLportVCSigPointer and adds
                support for fragmentation."
 -- 1.3.6.1.2.1.10.44.3.1.7 --  ::= { frnetservGroups 7 }

frnetservPVCEndptGroup2 OBJECT-GROUP
        OBJECTS {
                frPVCEndptInDiscardsDESet,
                frPVCEndptInFramesFECNSet,
                frPVCEndptOutFramesFECNSet,
                frPVCEndptInFramesBECNSet,
                frPVCEndptOutFramesBECNSet,
                frPVCEndptInCongDiscards,
                frPVCEndptInDECongDiscards,
                frPVCEndptOutCongDiscards,
                frPVCEndptOutDECongDiscards,
                frPVCEndptOutDEFrames,
                frPVCEndptAtmIwfConnIndex }
        STATUS current
        DESCRIPTION
               "Additions to the PVC end-point group.  These
                additions provide new frame counters to track
                frame loss.  In addition, the new FR/ATM IWF MIB
                cross-connect index is included."
 -- 1.3.6.1.2.1.10.44.3.1.8 --  ::= { frnetservGroups 8 }

frnetservPVCConnectNamesGroup OBJECT-GROUP
        OBJECTS {
                frPVCConnectUserName,
                frPVCConnectProviderName }
        STATUS current
        DESCRIPTION
               "Additions to the PVC Connect Group."
 -- 1.3.6.1.2.1.10.44.3.1.9 --  ::= { frnetservGroups 9 }

frnetservLportAdminGroup OBJECT-GROUP
        OBJECTS {
                frLportDLCIIndexValue,
                frLportTypeAdmin,
                frLportVCSigProtocolAdmin }
        STATUS current
        DESCRIPTION
               "Administrative (R/W) objects for creating a
                switch logical port."
 -- 1.3.6.1.2.1.10.44.3.1.10 --  ::= { frnetservGroups 10 }

frnetservMgtVCSigAdminGroup OBJECT-GROUP
        OBJECTS {
                frMgtVCSigProcedAdmin,
                frMgtVCSigUserN391Admin,
                frMgtVCSigUserN392Admin,
                frMgtVCSigUserN393Admin,
                frMgtVCSigUserT391Admin,
                frMgtVCSigNetN392Admin,
                frMgtVCSigNetN393Admin,
                frMgtVCSigNetT392Admin,
                frMgtVCSigNetnT3Admin }
        STATUS current
        DESCRIPTION
               "A collection of objects providing information
                applicable to the Local In-Channel Signaling
                Procedures used for a UNI/NNI logical port."
 -- 1.3.6.1.2.1.10.44.3.1.11 --  ::= { frnetservGroups 11 }

frnetservPVCNotifGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
                frPVCConnectStatusChange }
        STATUS deprecated
        DESCRIPTION
               "Deprecated notification group.  The
                frPVCConnectStatusChange notification was flawed
                because it included redundant indexes and was not
                properly encoded for SMIv1 conversion."
 -- 1.3.6.1.2.1.10.44.3.1.12 --  ::= { frnetservGroups 12 }

frnetservPVCNotifGroup2 NOTIFICATION-GROUP
        NOTIFICATIONS {
                frPVCConnectStatusNotif }
        STATUS current
        DESCRIPTION
               "A collection of notifications that apply to frame
                relay PVC Connections"
 -- 1.3.6.1.2.1.10.44.3.1.13 --  ::= { frnetservGroups 13 }

END
-- 
--    Copyright (C) The Internet Society (2000).  All Rights Reserved.
-- 
--    This document and translations of it may be copied and furnished to
--    others, and derivative works that comment on or otherwise explain it
--    or assist in its implementation may be prepared, copied, published
--    and distributed, in whole or in part, without restriction of any
--    kind, provided that the above copyright notice and this paragraph are
--    included on all such copies and derivative works.  However, this
--    document itself may not be modified in any way, such as by removing
--    the copyright notice or references to the Internet Society or other
--    Internet organizations, except as needed for the purpose of
--    developing Internet standards in which case the procedures for
--    copyrights defined in the Internet Standards process must be
--    followed, or as required to translate it into languages other than
--    English.
-- 
--    The limited permissions granted above are perpetual and will not be
--    revoked by the Internet Society or its successors or assigns.
-- 
--    This document and the information contained herein is provided on an
--    "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
--    TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
--    BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
--    HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
--    MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--