-- extracted from rfc2837.txt
-- at Thu Jun  1 07:07:27 2000

FIBRE-CHANNEL-FE-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        Unsigned32,
        Counter32,
        Gauge32,
        Integer32,
        mib-2
                FROM SNMPv2-SMI
        TEXTUAL-CONVENTION,
        TruthValue,
        TimeStamp
                FROM SNMPv2-TC
        SnmpAdminString
                FROM SNMP-FRAMEWORK-MIB
        MODULE-COMPLIANCE,
        OBJECT-GROUP
                FROM SNMPv2-CONF;

fcFeMIB MODULE-IDENTITY
        LAST-UPDATED "200005180000Z"       -- May 18, 2000 12:00:00 AM
        ORGANIZATION "IETF IPFC Working Group"
        CONTACT-INFO
               "Kha Sin Teow
                 Brocade Communications Systems,
                 1901 Guadalupe Parkway,
                 San Jose, CA 95131
                 U.S.A
                 Tel: +1 408 487 8180
                 Fax: +1 408 487 8190
                 Email: khasin@Brocade.COM

                WG Mailing list:ipfc@standards.gadzoox.com
                To Subscribe: ipfc-request@standards.gadzoox.com
                In Body: subscribe"
        DESCRIPTION
               "The MIB module for Fibre Channel Fabric Element."
        REVISION "200005180000Z"   -- May 18, 2000 12:00:00 AM
        DESCRIPTION
               "Initial revision, published as RFC 2837."
 -- 1.3.6.1.2.1.75 --  ::= { mib-2 75 }


-- Textual Conventions

MilliSeconds ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents time unit value in milliseconds."
        SYNTAX Unsigned32


MicroSeconds ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents time unit value in microseconds."
        SYNTAX Unsigned32


FcNameId ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the Worldwide Name associated with
                a Fibre Channel (FC) entity."
        SYNTAX OCTET STRING (SIZE (8))


FcAddressId ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents Fibre Channel Address ID, a 24-bit
                value unique within the address space of a Fabric."
        SYNTAX OCTET STRING (SIZE (3))


FcRxDataFieldSize ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the receive data field size of an
                NxPort or FxPort."
        SYNTAX Integer32 (128..2112)


FcBbCredit ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the buffer-to-buffer credit of an
                NxPort or FxPort."
        SYNTAX Integer32 (0..32767)


FcphVersion ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the version of FC-PH supported by an
                NxPort or FxPort."
        SYNTAX Integer32 (0..255)


FcStackedConnMode ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents an enumerated value used to indicate
                the Class 1 Stacked Connect Mode supported by
                an NxPort or FxPort."
        SYNTAX INTEGER {
                        none(1),
                        transparent(2),
                        lockedDown(3) }


FcCosCap ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the class of service capability of an
                NxPort or FxPort."
        SYNTAX BITS {
                        classF(0),
                        class1(1),
                        class2(2),
                        class3(3),
                        class4(4),
                        class5(5),
                        class6(6) }


FcFeModuleCapacity ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the maximum number of modules within
                a Fabric Element."
        SYNTAX Unsigned32


FcFeFxPortCapacity ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the maximum number of FxPorts within
                a module."
        SYNTAX Unsigned32


FcFeModuleIndex ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the module index within a conceptual table."
        SYNTAX Unsigned32


FcFeFxPortIndex ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the FxPort index within a conceptual table."
        SYNTAX Unsigned32


FcFeNxPortIndex ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the NxPort index within a conceptual table."
        SYNTAX Integer32 (1..126)


FcBbCreditModel ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
               "Represents the BB_Credit model of an FxPort."
        SYNTAX INTEGER {
                        regular(1),
                        alternate(2) }


fcFeMIBObjects OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.1 --  ::= { fcFeMIB 1 }

--  Note:
--  fcFeMIBConformance OBJECT IDENTIFIER ::= { fcFeMIB 2 }
--  see at the end of the module
-- Groups under fcFeMIBObjects

fcFeConfig OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.1.1 --  ::= { fcFeMIBObjects 1 }

fcFeStatus OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.1.2 --  ::= { fcFeMIBObjects 2 }

fcFeError OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.1.3 --  ::= { fcFeMIBObjects 3 }

fcFeAccounting OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.1.4 --  ::= { fcFeMIBObjects 4 }

fcFeCapabilities OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.1.5 --  ::= { fcFeMIBObjects 5 }

-- The Configuration group
-- This group consists of scalar objects and tables.
-- It contains the configuration and service parameters
-- of the Fabric Element and the FxPorts.
-- The group represents a set of parameters associated with
-- the Fabric Element  or an FxPort to support its NxPorts.

fcFeFabricName OBJECT-TYPE
        SYNTAX FcNameId
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The Name_Identifier of the Fabric to which this Fabric
                Element belongs."
 -- 1.3.6.1.2.1.75.1.1.1 --  ::= { fcFeConfig 1 }


fcFeElementName OBJECT-TYPE
        SYNTAX FcNameId
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The Name_Identifier of the Fabric Element."
 -- 1.3.6.1.2.1.75.1.1.2 --  ::= { fcFeConfig 2 }


fcFeModuleCapacity OBJECT-TYPE
        SYNTAX FcFeModuleCapacity
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The maximum number of modules in the Fabric Element,
                regardless of their current state."
 -- 1.3.6.1.2.1.75.1.1.3 --  ::= { fcFeConfig 3 }


-- The Module Table.
-- This table contains one entry for each module,
-- information of the modules.

fcFeModuleTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFeModuleEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each module in the
                Fabric Element, information of the modules."
 -- 1.3.6.1.2.1.75.1.1.4 --  ::= { fcFeConfig 4 }


fcFeModuleEntry OBJECT-TYPE
        SYNTAX FcFeModuleEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing the configuration parameters of a
                module."
        INDEX {
                fcFeModuleIndex }
 -- 1.3.6.1.2.1.75.1.1.4.1 --  ::= { fcFeModuleTable 1 }


FcFeModuleEntry ::= SEQUENCE {
        fcFeModuleIndex          FcFeModuleIndex,
        fcFeModuleDescr          SnmpAdminString,
        fcFeModuleObjectID       OBJECT IDENTIFIER,
        fcFeModuleOperStatus     INTEGER,
        fcFeModuleLastChange     TimeStamp,
        fcFeModuleFxPortCapacity FcFeFxPortCapacity,
        fcFeModuleName           FcNameId }


fcFeModuleIndex OBJECT-TYPE
        SYNTAX FcFeModuleIndex
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "This object identifies the module within the Fabric Element
                for which this entry contains information. This value is
                never greater than fcFeModuleCapacity."
 -- 1.3.6.1.2.1.75.1.1.4.1.1 --  ::= { fcFeModuleEntry 1 }


fcFeModuleDescr OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A textual description of the module. This value should
                include the full name and version identification of the
                module."
 -- 1.3.6.1.2.1.75.1.1.4.1.2 --  ::= { fcFeModuleEntry 2 }


fcFeModuleObjectID OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The vendor's authoritative identification of the module.
                This value may be allocated within the SMI enterprises
                subtree (1.3.6.1.4.1) and provides a straight-forward and
                unambiguous means for determining what kind of module is
                being managed.

                For example, this object could take the value
                1.3.6.1.4.1.99649.3.9 if vendor 'Neufe Inc.' was assigned
                the subtree 1.3.6.1.4.1.99649, and had assigned the
                identifier 1.3.6.1.4.1.99649.3.9 to its 'FeFiFo-16
                PlugInCard.'"
 -- 1.3.6.1.2.1.75.1.1.4.1.3 --  ::= { fcFeModuleEntry 3 }


fcFeModuleOperStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        online(1),   -- functional
                        offline(2),  -- not available
                        testing(3),  -- under testing
                        faulty(4)    -- defective
                        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "This object indicates the operational status of the module:
                online(1)   the module is functioning properly;
                offline(2)  the module is not available;
                testing(3)  the module is under testing; and
                faulty(4)   the module is defective in some way."
 -- 1.3.6.1.2.1.75.1.1.4.1.4 --  ::= { fcFeModuleEntry 4 }


fcFeModuleLastChange OBJECT-TYPE
        SYNTAX TimeStamp
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "This object contains the value of sysUpTime when the module
                entered its current operational status. A value of zero
                indicates that the operational status of the module has not
                changed since the agent last restarted."
 -- 1.3.6.1.2.1.75.1.1.4.1.5 --  ::= { fcFeModuleEntry 5 }


fcFeModuleFxPortCapacity OBJECT-TYPE
        SYNTAX FcFeFxPortCapacity
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of FxPort that can be contained within the
                module. Within each module, the ports are uniquely numbered
                in the range from 1 to fcFeModuleFxPortCapacity inclusive.
                However, the numbers are not required to be contiguous."
 -- 1.3.6.1.2.1.75.1.1.4.1.6 --  ::= { fcFeModuleEntry 6 }


fcFeModuleName OBJECT-TYPE
        SYNTAX FcNameId
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The Name_Identifier of the module."
 -- 1.3.6.1.2.1.75.1.1.4.1.7 --  ::= { fcFeModuleEntry 7 }


-- the FxPort Configuration Table.
-- This table contains, one entry for each FxPort,
-- configuration parameters of the ports.

fcFxPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort in the
                Fabric Element, configuration and service parameters of the
                FxPorts."
 -- 1.3.6.1.2.1.75.1.1.5 --  ::= { fcFeConfig 5 }


fcFxPortEntry OBJECT-TYPE
        SYNTAX FcFxPortEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing the configuration and service parameters
                of a FxPort."
        INDEX {
                fcFeModuleIndex,
                fcFxPortIndex }
 -- 1.3.6.1.2.1.75.1.1.5.1 --  ::= { fcFxPortTable 1 }


FcFxPortEntry ::= SEQUENCE {
        fcFxPortIndex             FcFeFxPortIndex,
        fcFxPortName              FcNameId,
        fcFxPortFcphVersionHigh   FcphVersion,
        fcFxPortFcphVersionLow    FcphVersion,
        fcFxPortBbCredit          FcBbCredit,
        fcFxPortRxBufSize         FcRxDataFieldSize,
        fcFxPortRatov             MilliSeconds,
        fcFxPortEdtov             MilliSeconds,
        fcFxPortCosSupported      FcCosCap,
        fcFxPortIntermixSupported TruthValue,
        fcFxPortStackedConnMode   FcStackedConnMode,
        fcFxPortClass2SeqDeliv    TruthValue,
        fcFxPortClass3SeqDeliv    TruthValue,
        fcFxPortHoldTime          MicroSeconds }


fcFxPortIndex OBJECT-TYPE
        SYNTAX FcFeFxPortIndex
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "This object identifies the FxPort within the module.  This
                number ranges from 1 to the value of fcFeModulePortCapacity
                for the associated module. The value remains constant for
                the identified FxPort until the module is re-initialized."
 -- 1.3.6.1.2.1.75.1.1.5.1.1 --  ::= { fcFxPortEntry 1 }


fcFxPortName OBJECT-TYPE
        SYNTAX FcNameId
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The World_wide Name of this FxPort.  Each FxPort has a
                unique Port World_wide Name within the Fabric."
 -- 1.3.6.1.2.1.75.1.1.5.1.2 --  ::= { fcFxPortEntry 2 }


-- FxPort common service parameters

fcFxPortFcphVersionHigh OBJECT-TYPE
        SYNTAX FcphVersion
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The highest or most recent version of FC-PH that the FxPort
                is configured to support."
 -- 1.3.6.1.2.1.75.1.1.5.1.3 --  ::= { fcFxPortEntry 3 }


fcFxPortFcphVersionLow OBJECT-TYPE
        SYNTAX FcphVersion
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The lowest or earliest version of FC-PH that the FxPort is
                configured to support."
 -- 1.3.6.1.2.1.75.1.1.5.1.4 --  ::= { fcFxPortEntry 4 }


fcFxPortBbCredit OBJECT-TYPE
        SYNTAX FcBbCredit
        UNITS
               "buffers"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The total number of receive buffers available for holding
                Class 1 connect-request, Class 2 or 3 frames from the
                attached NxPort.  It is for buffer-to-buffer flow control
                in the direction from the attached NxPort (if applicable)
                to FxPort."
 -- 1.3.6.1.2.1.75.1.1.5.1.5 --  ::= { fcFxPortEntry 5 }


fcFxPortRxBufSize OBJECT-TYPE
        SYNTAX FcRxDataFieldSize
        UNITS
               "bytes"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The largest Data_Field Size (in octets) for an FT_1 frame
                that can be received by the FxPort."
 -- 1.3.6.1.2.1.75.1.1.5.1.6 --  ::= { fcFxPortEntry 6 }


fcFxPortRatov OBJECT-TYPE
        SYNTAX MilliSeconds
        UNITS
               "milliseconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The Resource_Allocation_Timeout Value configured for the
                FxPort.  This is used as the timeout value for determining
                when to reuse an NxPort resource such as a
                Recovery_Qualifier.  It represents E_D_TOV (see next
                object) plus twice the maximum time that a frame may be
                delayed within the Fabric and still be delivered."
 -- 1.3.6.1.2.1.75.1.1.5.1.7 --  ::= { fcFxPortEntry 7 }


fcFxPortEdtov OBJECT-TYPE
        SYNTAX MilliSeconds
        UNITS
               "milliseconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The E_D_TOV value configured for the FxPort. The
                Error_Detect_Timeout Value is used as the timeout value for
                detecting an error condition."
 -- 1.3.6.1.2.1.75.1.1.5.1.8 --  ::= { fcFxPortEntry 8 }


-- FxPort class service parameters

fcFxPortCosSupported OBJECT-TYPE
        SYNTAX FcCosCap
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A value indicating the set of Classes of Service supported
                by the FxPort."
 -- 1.3.6.1.2.1.75.1.1.5.1.9 --  ::= { fcFxPortEntry 9 }


fcFxPortIntermixSupported OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether or not the FxPort supports an
                Intermixed Dedicated Connection."
 -- 1.3.6.1.2.1.75.1.1.5.1.10 --  ::= { fcFxPortEntry 10 }


fcFxPortStackedConnMode OBJECT-TYPE
        SYNTAX FcStackedConnMode
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A value indicating the mode of Stacked Connect supported by
                the FxPort."
 -- 1.3.6.1.2.1.75.1.1.5.1.11 --  ::= { fcFxPortEntry 11 }


fcFxPortClass2SeqDeliv OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether or not Class 2 Sequential
                Delivery is supported by the FxPort."
 -- 1.3.6.1.2.1.75.1.1.5.1.12 --  ::= { fcFxPortEntry 12 }


fcFxPortClass3SeqDeliv OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether or not Class 3 Sequential
                Delivery is supported by the FxPort."
 -- 1.3.6.1.2.1.75.1.1.5.1.13 --  ::= { fcFxPortEntry 13 }


-- other FxPort parameters

fcFxPortHoldTime OBJECT-TYPE
        SYNTAX MicroSeconds
        UNITS
               "microseconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The maximum time (in microseconds) that the FxPort shall
                hold a frame before discarding the frame if it is unable to
                deliver the frame. The value 0 means that the FxPort does
                not support this parameter."
 -- 1.3.6.1.2.1.75.1.1.5.1.14 --  ::= { fcFxPortEntry 14 }


-- the Status group
-- This group consists of tables that contains operational
-- status and established service parameters for the Fabric
-- Element and the attached NxPorts.
-- The FxPort Status table
-- This table contains, one entry for each FxPort,
-- the operational status and parameters of the FxPorts.

fcFxPortStatusTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortStatusEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort in the
                Fabric Element, operational status and parameters of the
                FxPorts."
 -- 1.3.6.1.2.1.75.1.2.1 --  ::= { fcFeStatus 1 }


fcFxPortStatusEntry OBJECT-TYPE
        SYNTAX FcFxPortStatusEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing operational status and parameters of a
                FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.2.1.1 --  ::= { fcFxPortStatusTable 1 }


FcFxPortStatusEntry ::= SEQUENCE {
        fcFxPortID                FcAddressId,
        fcFxPortBbCreditAvailable Gauge32,
        fcFxPortOperMode          INTEGER,
        fcFxPortAdminMode         INTEGER }


fcFxPortID OBJECT-TYPE
        SYNTAX FcAddressId
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The address identifier by which this FxPort is identified
                within the Fabric.  The FxPort may assign its address
                identifier to its attached NxPort(s) during Fabric Login."
 -- 1.3.6.1.2.1.75.1.2.1.1.1 --  ::= { fcFxPortStatusEntry 1 }


fcFxPortBbCreditAvailable OBJECT-TYPE
        SYNTAX Gauge32
        UNITS
               "buffers"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of buffers currently available for receiving
                frames from the attached port in the buffer-to-buffer flow
                control. The value should be less than or equal to
                fcFxPortBbCredit."
 -- 1.3.6.1.2.1.75.1.2.1.1.2 --  ::= { fcFxPortStatusEntry 2 }


fcFxPortOperMode OBJECT-TYPE
        SYNTAX INTEGER {
                        unknown(1),
                        fPort(2),
                        flPort(3) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The current operational mode of the FxPort."
 -- 1.3.6.1.2.1.75.1.2.1.1.3 --  ::= { fcFxPortStatusEntry 3 }


fcFxPortAdminMode OBJECT-TYPE
        SYNTAX INTEGER {
                        fPort(2),
                        flPort(3) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The desired operational mode of the FxPort."
 -- 1.3.6.1.2.1.75.1.2.1.1.4 --  ::= { fcFxPortStatusEntry 4 }


-- the FxPort Physical Level table
-- This table contains, one entry for each FxPort in the
-- Fabric Element, the physical level status and parameters
-- of the FxPorts.

fcFxPortPhysTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortPhysEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort in the
                Fabric Element, physical level status and parameters of the
                FxPorts."
 -- 1.3.6.1.2.1.75.1.2.2 --  ::= { fcFeStatus 2 }


fcFxPortPhysEntry OBJECT-TYPE
        SYNTAX FcFxPortPhysEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing physical level status and parameters of
                a FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.2.2.1 --  ::= { fcFxPortPhysTable 1 }


FcFxPortPhysEntry ::= SEQUENCE {
        fcFxPortPhysAdminStatus INTEGER,
        fcFxPortPhysOperStatus  INTEGER,
        fcFxPortPhysLastChange  TimeStamp,
        fcFxPortPhysRttov       MilliSeconds }


fcFxPortPhysAdminStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        online(1),   -- place port online
                        offline(2),  -- take port offline
                        testing(3)   -- initiate test procedures
                        }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The desired state of the FxPort.  A management station may
                place the FxPort in a desired state by setting this object
                accordingly.  The testing(3) state indicates that no
                operational frames can be passed.  When a Fabric Element
                initializes, all FxPorts start with fcFxPortPhysAdminStatus
                in the offline(2) state.  As the result of either explicit
                management action or per configuration information
                accessible by the Fabric Element, fcFxPortPhysAdminStatus
                is then changed to either the online(1) or testing(3)
                states, or remains in the offline state."
 -- 1.3.6.1.2.1.75.1.2.2.1.1 --  ::= { fcFxPortPhysEntry 1 }


fcFxPortPhysOperStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        online(1),           -- Login may proceed
                        offline(2),          -- Login cannot proceed
                        testing(3),          -- port is under test
                        linkFailure(4)       -- failure after online/testing
                        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The current operational status of the FxPort.  The
                testing(3) indicates that no operational frames can be
                passed.  If fcFxPortPhysAdminStatus is offline(2) then
                fcFxPortPhysOperStatus should be offline(2). If
                fcFxPortPhysAdminStatus is changed to online(1) then
                fcFxPortPhysOperStatus should change to online(1) if the
                FxPort is ready to accept Fabric Login request from the
                attached NxPort; it should proceed and remain in the link-
                failure(4) state if and only if there is a fault that
                prevents it from going to the online(1) state."
 -- 1.3.6.1.2.1.75.1.2.2.1.2 --  ::= { fcFxPortPhysEntry 2 }


fcFxPortPhysLastChange OBJECT-TYPE
        SYNTAX TimeStamp
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The value of sysUpTime at the time the FxPort entered its
                current operational status. A value of zero indicates that
                the FxPort's operational status has not changed since the
                agent last restarted."
 -- 1.3.6.1.2.1.75.1.2.2.1.3 --  ::= { fcFxPortPhysEntry 3 }


fcFxPortPhysRttov OBJECT-TYPE
        SYNTAX MilliSeconds
        UNITS
               "milliseconds"
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "The Receiver_Transmitter_Timeout value of the FxPort. This
                is used by the receiver logic to detect Loss of
                Synchronization."
 -- 1.3.6.1.2.1.75.1.2.2.1.4 --  ::= { fcFxPortPhysEntry 4 }


-- The FxPort Fabric Login table
--
-- This table contains, one entry for each FxPort in the
-- Fabric Element, the Service Parameters that have been
-- established from the most recent Fabric Login,
-- implicit or explicit.

fcFxLoginTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxLoginEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each NxPort attached
                to a particular FxPort in the Fabric Element, services
                parameters established from the most recent Fabric Login,
                explicit or implicit. Note that an FxPort may have one or
                more NxPort attached to it."
 -- 1.3.6.1.2.1.75.1.2.3 --  ::= { fcFeStatus 3 }


fcFxLoginEntry OBJECT-TYPE
        SYNTAX FcFxLoginEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing service parameters established from a
                successful Fabric Login."
        INDEX {
                fcFeModuleIndex,
                fcFxPortIndex,
                fcFxPortNxLoginIndex }
 -- 1.3.6.1.2.1.75.1.2.3.1 --  ::= { fcFxLoginTable 1 }


FcFxLoginEntry ::= SEQUENCE {
        fcFxPortNxLoginIndex          FcFeNxPortIndex,
        fcFxPortFcphVersionAgreed     FcphVersion,
        fcFxPortNxPortBbCredit        FcBbCredit,
        fcFxPortNxPortRxDataFieldSize FcRxDataFieldSize,
        fcFxPortCosSuppAgreed         FcCosCap,
        fcFxPortIntermixSuppAgreed    TruthValue,
        fcFxPortStackedConnModeAgreed FcStackedConnMode,
        fcFxPortClass2SeqDelivAgreed  TruthValue,
        fcFxPortClass3SeqDelivAgreed  TruthValue,
        fcFxPortNxPortName            FcNameId,
        fcFxPortConnectedNxPort       FcAddressId,
        fcFxPortBbCreditModel         FcBbCreditModel }


fcFxPortNxLoginIndex OBJECT-TYPE
        SYNTAX FcFeNxPortIndex
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "The object identifies the associated NxPort in the
                attachment for which the entry contains information."
 -- 1.3.6.1.2.1.75.1.2.3.1.1 --  ::= { fcFxLoginEntry 1 }


fcFxPortFcphVersionAgreed OBJECT-TYPE
        SYNTAX FcphVersion
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The version of FC-PH that the FxPort has agreed to support
                from the Fabric Login"
 -- 1.3.6.1.2.1.75.1.2.3.1.2 --  ::= { fcFxLoginEntry 2 }


fcFxPortNxPortBbCredit OBJECT-TYPE
        SYNTAX FcBbCredit
        UNITS
               "buffers"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The total number of buffers available for holding Class 1
                connect-request, Class 2 or Class 3 frames to be
                transmitted to the attached NxPort.  It is for buffer-to-
                buffer flow control in the direction from FxPort to NxPort.
                The buffer-to-buffer flow control mechanism is indicated in
                the respective fcFxPortBbCreditModel."
 -- 1.3.6.1.2.1.75.1.2.3.1.3 --  ::= { fcFxLoginEntry 3 }


fcFxPortNxPortRxDataFieldSize OBJECT-TYPE
        SYNTAX FcRxDataFieldSize
        UNITS
               "bytes"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The Receive Data Field Size of the attached NxPort. This
                object specifies the largest Data Field Size for an FT_1
                frame that can be received by the NxPort."
 -- 1.3.6.1.2.1.75.1.2.3.1.4 --  ::= { fcFxLoginEntry 4 }


fcFxPortCosSuppAgreed OBJECT-TYPE
        SYNTAX FcCosCap
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A variable indicating that the attached NxPort has
                requested the FxPort for the support of classes of services
                and the FxPort has granted the request."
 -- 1.3.6.1.2.1.75.1.2.3.1.5 --  ::= { fcFxLoginEntry 5 }


fcFxPortIntermixSuppAgreed OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A variable indicating that the attached NxPort has
                requested the FxPort for the support of Intermix and the
                FxPort has granted the request. This flag is only valid if
                Class 1 service is supported."
 -- 1.3.6.1.2.1.75.1.2.3.1.6 --  ::= { fcFxLoginEntry 6 }


fcFxPortStackedConnModeAgreed OBJECT-TYPE
        SYNTAX FcStackedConnMode
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A variable indicating whether the FxPort has agreed to
                support stacked connect from the Fabric Login. This is only
                meaningful if Class 1 service has been agreed."
 -- 1.3.6.1.2.1.75.1.2.3.1.7 --  ::= { fcFxLoginEntry 7 }


fcFxPortClass2SeqDelivAgreed OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A variable indicating whether the FxPort has agreed to
                support Class 2 sequential delivery from the Fabric Login.
                This is only meaningful if Class 2 service has been
                agreed."
 -- 1.3.6.1.2.1.75.1.2.3.1.8 --  ::= { fcFxLoginEntry 8 }


fcFxPortClass3SeqDelivAgreed OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether the FxPort has agreed to support
                Class 3 sequential delivery from the Fabric Login. This is
                only meaningful if Class 3 service has been agreed."
 -- 1.3.6.1.2.1.75.1.2.3.1.9 --  ::= { fcFxLoginEntry 9 }


fcFxPortNxPortName OBJECT-TYPE
        SYNTAX FcNameId
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The port name of the attached NxPort."
 -- 1.3.6.1.2.1.75.1.2.3.1.10 --  ::= { fcFxLoginEntry 10 }


fcFxPortConnectedNxPort OBJECT-TYPE
        SYNTAX FcAddressId
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The address identifier of the destination NxPort with which
                this FxPort is currently engaged in a either a Class 1 or
                loop connection. If this FxPort is not engaged in a
                connection, then the value of this object is '000000'H."
 -- 1.3.6.1.2.1.75.1.2.3.1.11 --  ::= { fcFxLoginEntry 11 }


fcFxPortBbCreditModel OBJECT-TYPE
        SYNTAX FcBbCreditModel
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
               "This object identifies the BB_Credit model used by the
                FxPort."
 -- 1.3.6.1.2.1.75.1.2.3.1.12 --  ::= { fcFxLoginEntry 12 }


-- the Error group
-- This group consists of tables that contain information about
-- the various types of errors detected.  The management station
-- may use the information in this group to determine the
-- quality of the link between the FxPort and its attached NxPort.
-- the FxPort Error table
-- This table contains, one entry for each FxPort in the Fabric
-- Element, counters recording numbers of errors detected
-- since the management agent re-initialized.
-- The first 6 columnar objects after the port index corresponds
-- to the counters in the Link Error Status Block.

fcFxPortErrorTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortErrorEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort, counters
                that record the numbers of errors detected."
 -- 1.3.6.1.2.1.75.1.3.1 --  ::= { fcFeError 1 }


fcFxPortErrorEntry OBJECT-TYPE
        SYNTAX FcFxPortErrorEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing error counters of a FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.3.1.1 --  ::= { fcFxPortErrorTable 1 }


FcFxPortErrorEntry ::= SEQUENCE {
        fcFxPortLinkFailures       Counter32,
        fcFxPortSyncLosses         Counter32,
        fcFxPortSigLosses          Counter32,
        fcFxPortPrimSeqProtoErrors Counter32,
        fcFxPortInvalidTxWords     Counter32,
        fcFxPortInvalidCrcs        Counter32,
        fcFxPortDelimiterErrors    Counter32,
        fcFxPortAddressIdErrors    Counter32,
        fcFxPortLinkResetIns       Counter32,
        fcFxPortLinkResetOuts      Counter32,
        fcFxPortOlsIns             Counter32,
        fcFxPortOlsOuts            Counter32 }


fcFxPortLinkFailures OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of link failures detected by this FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.1 --  ::= { fcFxPortErrorEntry 1 }


fcFxPortSyncLosses OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of loss of synchronization detected by the
                FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.2 --  ::= { fcFxPortErrorEntry 2 }


fcFxPortSigLosses OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of loss of signal detected by the FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.3 --  ::= { fcFxPortErrorEntry 3 }


fcFxPortPrimSeqProtoErrors OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of primitive sequence protocol errors detected
                by the FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.4 --  ::= { fcFxPortErrorEntry 4 }


fcFxPortInvalidTxWords OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of invalid transmission word detected by the
                FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.5 --  ::= { fcFxPortErrorEntry 5 }


fcFxPortInvalidCrcs OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of invalid CRC detected by this FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.6 --  ::= { fcFxPortErrorEntry 6 }


fcFxPortDelimiterErrors OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Delimiter Errors detected by this FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.7 --  ::= { fcFxPortErrorEntry 7 }


fcFxPortAddressIdErrors OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of address identifier errors detected by this
                FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.8 --  ::= { fcFxPortErrorEntry 8 }


fcFxPortLinkResetIns OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Link Reset Protocol received by this FxPort
                from the attached NxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.9 --  ::= { fcFxPortErrorEntry 9 }


fcFxPortLinkResetOuts OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Link Reset Protocol issued by this FxPort to
                the attached NxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.10 --  ::= { fcFxPortErrorEntry 10 }


fcFxPortOlsIns OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Offline Sequence received by this FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.11 --  ::= { fcFxPortErrorEntry 11 }


fcFxPortOlsOuts OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Offline Sequence issued by this FxPort."
 -- 1.3.6.1.2.1.75.1.3.1.1.12 --  ::= { fcFxPortErrorEntry 12 }


-- Accounting Groups:
-- (1) Class 1 Accounting Group,
-- (2) Class 2 Accounting Group, and
-- (3) Class 3 Accounting Group.
-- Each group consists of a table that contains accounting
-- information for the FxPorts in the Fabric Element.
-- the Class 1 Accounting table
-- This table contains, one entry for each FxPort in the Fabric
-- Element, Counter32s for certain types of events occurred in the
-- the FxPorts since the the management agent has re-initialized.

fcFxPortC1AccountingTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortC1AccountingEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort in the
                Fabric Element, Class 1 accounting information recorded
                since the management agent has re-initialized."
 -- 1.3.6.1.2.1.75.1.4.1 --  ::= { fcFeAccounting 1 }


fcFxPortC1AccountingEntry OBJECT-TYPE
        SYNTAX FcFxPortC1AccountingEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing Class 1 accounting information for each
                FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.4.1.1 --  ::= { fcFxPortC1AccountingTable 1 }


FcFxPortC1AccountingEntry ::= SEQUENCE {
        fcFxPortC1InFrames       Counter32,
        fcFxPortC1OutFrames      Counter32,
        fcFxPortC1InOctets       Counter32,
        fcFxPortC1OutOctets      Counter32,
        fcFxPortC1Discards       Counter32,
        fcFxPortC1FbsyFrames     Counter32,
        fcFxPortC1FrjtFrames     Counter32,
        fcFxPortC1InConnections  Counter32,
        fcFxPortC1OutConnections Counter32,
        fcFxPortC1ConnTime       MilliSeconds }


fcFxPortC1InFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 frames (other than Class 1 connect-
                request) received by this FxPort from its attached NxPort."
 -- 1.3.6.1.2.1.75.1.4.1.1.1 --  ::= { fcFxPortC1AccountingEntry 1 }


fcFxPortC1OutFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 frames (other than Class 1 connect-
                request) delivered through this FxPort to its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.1.1.2 --  ::= { fcFxPortC1AccountingEntry 2 }


fcFxPortC1InOctets OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 frame octets, including the frame
                delimiters,  received by this FxPort from its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.1.1.3 --  ::= { fcFxPortC1AccountingEntry 3 }


fcFxPortC1OutOctets OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 frame octets, including the frame
                delimiters, delivered through this FxPort its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.1.1.4 --  ::= { fcFxPortC1AccountingEntry 4 }


fcFxPortC1Discards OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 frames discarded by this FxPort."
 -- 1.3.6.1.2.1.75.1.4.1.1.5 --  ::= { fcFxPortC1AccountingEntry 5 }


fcFxPortC1FbsyFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of F_BSY frames generated by this FxPort against
                Class 1 connect-request."
 -- 1.3.6.1.2.1.75.1.4.1.1.6 --  ::= { fcFxPortC1AccountingEntry 6 }


fcFxPortC1FrjtFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of F_RJT frames generated by this FxPort against
                Class 1 connect-request."
 -- 1.3.6.1.2.1.75.1.4.1.1.7 --  ::= { fcFxPortC1AccountingEntry 7 }


fcFxPortC1InConnections OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 connections successfully established
                in which the attached NxPort is the source of the connect-
                request."
 -- 1.3.6.1.2.1.75.1.4.1.1.8 --  ::= { fcFxPortC1AccountingEntry 8 }


fcFxPortC1OutConnections OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 1 connections successfully established
                in which the attached NxPort is the destination of the
                connect-request."
 -- 1.3.6.1.2.1.75.1.4.1.1.9 --  ::= { fcFxPortC1AccountingEntry 9 }


fcFxPortC1ConnTime OBJECT-TYPE
        SYNTAX MilliSeconds
        UNITS
               "milliseconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The cumulative time that this FxPort has been engaged in
                Class 1 connection.  The amount of time is counted from
                after a connect-request has been accepted until the
                connection is disengaged, either by an EOFdt or Link
                Reset."
 -- 1.3.6.1.2.1.75.1.4.1.1.10 --  ::= { fcFxPortC1AccountingEntry 10 }


-- the Class 2 Accounting table
-- This table contains, one entry for each FxPort in the Fabric
-- Element, Counter32s for certain types of events occurred in the
-- the FxPorts since the the management agent has re-initialized.

fcFxPortC2AccountingTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortC2AccountingEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort in the
                Fabric Element, Class 2 accounting information recorded
                since the management agent has re-initialized."
 -- 1.3.6.1.2.1.75.1.4.2 --  ::= { fcFeAccounting 2 }


fcFxPortC2AccountingEntry OBJECT-TYPE
        SYNTAX FcFxPortC2AccountingEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing Class 2 accounting information for each
                FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.4.2.1 --  ::= { fcFxPortC2AccountingTable 1 }


FcFxPortC2AccountingEntry ::= SEQUENCE {
        fcFxPortC2InFrames   Counter32,
        fcFxPortC2OutFrames  Counter32,
        fcFxPortC2InOctets   Counter32,
        fcFxPortC2OutOctets  Counter32,
        fcFxPortC2Discards   Counter32,
        fcFxPortC2FbsyFrames Counter32,
        fcFxPortC2FrjtFrames Counter32 }


fcFxPortC2InFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 2 frames received by this FxPort from
                its attached NxPort."
 -- 1.3.6.1.2.1.75.1.4.2.1.1 --  ::= { fcFxPortC2AccountingEntry 1 }


fcFxPortC2OutFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 2 frames delivered through this FxPort
                to its attached NxPort."
 -- 1.3.6.1.2.1.75.1.4.2.1.2 --  ::= { fcFxPortC2AccountingEntry 2 }


fcFxPortC2InOctets OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 2 frame octets, including the frame
                delimiters, received by this FxPort from its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.2.1.3 --  ::= { fcFxPortC2AccountingEntry 3 }


fcFxPortC2OutOctets OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 2 frame octets, including the frame
                delimiters, delivered through this FxPort to its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.2.1.4 --  ::= { fcFxPortC2AccountingEntry 4 }


fcFxPortC2Discards OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 2 frames discarded by this FxPort."
 -- 1.3.6.1.2.1.75.1.4.2.1.5 --  ::= { fcFxPortC2AccountingEntry 5 }


fcFxPortC2FbsyFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of F_BSY frames generated by this FxPort against
                Class 2 frames."
 -- 1.3.6.1.2.1.75.1.4.2.1.6 --  ::= { fcFxPortC2AccountingEntry 6 }


fcFxPortC2FrjtFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of F_RJT frames generated by this FxPort against
                Class 2 frames."
 -- 1.3.6.1.2.1.75.1.4.2.1.7 --  ::= { fcFxPortC2AccountingEntry 7 }


-- the Class 3 Accounting Group
-- This table contains, one entry for each FxPort in the Fabric
-- Element, Counter32s for certain types of events occurred in the
-- the FxPorts since the management agent has re-initialized.

fcFxPortC3AccountingTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortC3AccountingEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort in the
                Fabric Element, Class 3 accounting information recorded
                since the management agent has re-initialized."
 -- 1.3.6.1.2.1.75.1.4.3 --  ::= { fcFeAccounting 3 }


fcFxPortC3AccountingEntry OBJECT-TYPE
        SYNTAX FcFxPortC3AccountingEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing Class 3 accounting information for each
                FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.4.3.1 --  ::= { fcFxPortC3AccountingTable 1 }


FcFxPortC3AccountingEntry ::= SEQUENCE {
        fcFxPortC3InFrames  Counter32,
        fcFxPortC3OutFrames Counter32,
        fcFxPortC3InOctets  Counter32,
        fcFxPortC3OutOctets Counter32,
        fcFxPortC3Discards  Counter32 }


fcFxPortC3InFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 3 frames received by this FxPort from
                its attached NxPort."
 -- 1.3.6.1.2.1.75.1.4.3.1.1 --  ::= { fcFxPortC3AccountingEntry 1 }


fcFxPortC3OutFrames OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 3 frames delivered through this FxPort
                to its attached NxPort."
 -- 1.3.6.1.2.1.75.1.4.3.1.2 --  ::= { fcFxPortC3AccountingEntry 2 }


fcFxPortC3InOctets OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 3 frame octets, including the frame
                delimiters, received by this FxPort from its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.3.1.3 --  ::= { fcFxPortC3AccountingEntry 3 }


fcFxPortC3OutOctets OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 3 frame octets, including the frame
                delimiters, delivered through this FxPort to its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.4.3.1.4 --  ::= { fcFxPortC3AccountingEntry 4 }


fcFxPortC3Discards OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The number of Class 3 frames discarded by this FxPort."
 -- 1.3.6.1.2.1.75.1.4.3.1.5 --  ::= { fcFxPortC3AccountingEntry 5 }


-- The Capability Group - consists of a table describing
-- information about what each FxPort is inherently capable
-- of operating or supporting.
-- A capability may be used, as expressed in its respective
-- object value in the Configuration group.

fcFxPortCapTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FcFxPortCapEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "A table that contains, one entry for each FxPort, the
                capabilities of the port within the Fabric Element."
 -- 1.3.6.1.2.1.75.1.5.1 --  ::= { fcFeCapabilities 1 }


fcFxPortCapEntry OBJECT-TYPE
        SYNTAX FcFxPortCapEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
               "An entry containing the Cap of a FxPort."
        AUGMENTS {
                fcFxPortEntry }
 -- 1.3.6.1.2.1.75.1.5.1.1 --  ::= { fcFxPortCapTable 1 }


FcFxPortCapEntry ::= SEQUENCE {
        fcFxPortCapFcphVersionHigh    FcphVersion,
        fcFxPortCapFcphVersionLow     FcphVersion,
        fcFxPortCapBbCreditMax        FcBbCredit,
        fcFxPortCapBbCreditMin        FcBbCredit,
        fcFxPortCapRxDataFieldSizeMax FcRxDataFieldSize,
        fcFxPortCapRxDataFieldSizeMin FcRxDataFieldSize,
        fcFxPortCapCos                FcCosCap,
        fcFxPortCapIntermix           TruthValue,
        fcFxPortCapStackedConnMode    FcStackedConnMode,
        fcFxPortCapClass2SeqDeliv     TruthValue,
        fcFxPortCapClass3SeqDeliv     TruthValue,
        fcFxPortCapHoldTimeMax        MicroSeconds,
        fcFxPortCapHoldTimeMin        MicroSeconds }


fcFxPortCapFcphVersionHigh OBJECT-TYPE
        SYNTAX FcphVersion
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The highest or most recent version of FC-PH that the FxPort
                is capable of supporting."
 -- 1.3.6.1.2.1.75.1.5.1.1.1 --  ::= { fcFxPortCapEntry 1 }


fcFxPortCapFcphVersionLow OBJECT-TYPE
        SYNTAX FcphVersion
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The lowest or earliest version of FC-PH that the FxPort is
                capable of supporting."
 -- 1.3.6.1.2.1.75.1.5.1.1.2 --  ::= { fcFxPortCapEntry 2 }


fcFxPortCapBbCreditMax OBJECT-TYPE
        SYNTAX FcBbCredit
        UNITS
               "buffers"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The maximum number of receive buffers available for holding
                Class 1 connect-request, Class 2 or Class 3 frames from the
                attached NxPort."
 -- 1.3.6.1.2.1.75.1.5.1.1.3 --  ::= { fcFxPortCapEntry 3 }


fcFxPortCapBbCreditMin OBJECT-TYPE
        SYNTAX FcBbCredit
        UNITS
               "buffers"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The minimum number of receive buffers available for holding
                Class 1 connect-request, Class 2 or Class 3 frames from the
                attached NxPort."
 -- 1.3.6.1.2.1.75.1.5.1.1.4 --  ::= { fcFxPortCapEntry 4 }


fcFxPortCapRxDataFieldSizeMax OBJECT-TYPE
        SYNTAX FcRxDataFieldSize
        UNITS
               "bytes"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The maximum size in bytes of the Data Field in a frame that
                the FxPort is capable of receiving from its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.5.1.1.5 --  ::= { fcFxPortCapEntry 5 }


fcFxPortCapRxDataFieldSizeMin OBJECT-TYPE
        SYNTAX FcRxDataFieldSize
        UNITS
               "bytes"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The minimum size in bytes of the Data Field in a frame that
                the FxPort is capable of receiving from its attached
                NxPort."
 -- 1.3.6.1.2.1.75.1.5.1.1.6 --  ::= { fcFxPortCapEntry 6 }


fcFxPortCapCos OBJECT-TYPE
        SYNTAX FcCosCap
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A value indicating the set of Classes of Service that the
                FxPort is capable of supporting."
 -- 1.3.6.1.2.1.75.1.5.1.1.7 --  ::= { fcFxPortCapEntry 7 }


fcFxPortCapIntermix OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether or not the FxPort is capable of
                supporting the intermixing of Class 2 and Class 3 frames
                during a Class 1 connection. This flag is only valid if the
                port is capable of supporting Class 1 service."
 -- 1.3.6.1.2.1.75.1.5.1.1.8 --  ::= { fcFxPortCapEntry 8 }


fcFxPortCapStackedConnMode OBJECT-TYPE
        SYNTAX FcStackedConnMode
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A value indicating the mode of Stacked Connect request that
                the FxPort is capable of supporting."
 -- 1.3.6.1.2.1.75.1.5.1.1.9 --  ::= { fcFxPortCapEntry 9 }


fcFxPortCapClass2SeqDeliv OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether or not the FxPort is capable of
                supporting Class 2 Sequential Delivery."
 -- 1.3.6.1.2.1.75.1.5.1.1.10 --  ::= { fcFxPortCapEntry 10 }


fcFxPortCapClass3SeqDeliv OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "A flag indicating whether or not the FxPort is capable of
                supporting Class 3 Sequential Delivery."
 -- 1.3.6.1.2.1.75.1.5.1.1.11 --  ::= { fcFxPortCapEntry 11 }


fcFxPortCapHoldTimeMax OBJECT-TYPE
        SYNTAX MicroSeconds
        UNITS
               "microseconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The maximum holding time (in microseconds) that the FxPort
                is capable of supporting."
 -- 1.3.6.1.2.1.75.1.5.1.1.12 --  ::= { fcFxPortCapEntry 12 }


fcFxPortCapHoldTimeMin OBJECT-TYPE
        SYNTAX MicroSeconds
        UNITS
               "microseconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "The minimum holding time (in microseconds) that the FxPort
                is capable of supporting."
 -- 1.3.6.1.2.1.75.1.5.1.1.13 --  ::= { fcFxPortCapEntry 13 }


-- conformance information

fcFeMIBConformance OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.2 --  ::= { fcFeMIB 2 }

fcFeMIBCompliances OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.2.1 --  ::= { fcFeMIBConformance 1 }

fcFeMIBGroups OBJECT IDENTIFIER 
 -- 1.3.6.1.2.1.75.2.2 --  ::= { fcFeMIBConformance 2 }


-- compliance statements

fcFeMIBMinimumCompliance MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION
               "The minimum compliance statement for SNMP entities
                which implement the FIBRE-CHANNEL-FE-MIB."

        MODULE 
        MANDATORY-GROUPS {
                        fcFeConfigGroup,
                        fcFeStatusGroup,
                        fcFeErrorGroup }

        OBJECT fcFeFabricName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFeElementName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFeModuleName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortAdminMode
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortPhysAdminStatus
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortPhysRttov
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortBbCreditModel
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
 -- 1.3.6.1.2.1.75.2.1.1 --  ::= { fcFeMIBCompliances 1 }


fcFeMIBFullCompliance MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION
               "The full compliance statement for SNMP entities
                which implement the FIBRE-CHANNEL-FE-MIB."

        MODULE 
        MANDATORY-GROUPS {
                        fcFeConfigGroup,
                        fcFeStatusGroup,
                        fcFeErrorGroup,
                        fcFeCapabilitiesGroup }

        GROUP fcFeClass1AccountingGroup
          DESCRIPTION
               "This group is mandatory for all fibre channel fabric
                elements which support class 1 frames."
        GROUP fcFeClass2AccountingGroup
          DESCRIPTION
               "This group is mandatory for all fibre channel fabric
                elements which support class 2 frames."
        GROUP fcFeClass3AccountingGroup
          DESCRIPTION
               "This group is mandatory for all fibre channel fabric
                elements which support class 3 frames."
        OBJECT fcFeFabricName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFeElementName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFeModuleName
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortAdminMode
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortPhysAdminStatus
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortPhysRttov
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
        OBJECT fcFxPortBbCreditModel
          MIN-ACCESS read-only
          DESCRIPTION 
               "Write access is not required."
 -- 1.3.6.1.2.1.75.2.1.2 --  ::= { fcFeMIBCompliances 2 }

-- units of conformance

fcFeConfigGroup OBJECT-GROUP
        OBJECTS {
                fcFeFabricName,
                fcFeElementName,
                fcFeModuleCapacity,
                fcFeModuleDescr,
                fcFeModuleObjectID,
                fcFeModuleOperStatus,
                fcFeModuleLastChange,
                fcFeModuleFxPortCapacity,
                fcFeModuleName,
                fcFxPortName,
                fcFxPortFcphVersionHigh,
                fcFxPortFcphVersionLow,
                fcFxPortBbCredit,
                fcFxPortRxBufSize,
                fcFxPortRatov,
                fcFxPortEdtov,
                fcFxPortCosSupported,
                fcFxPortIntermixSupported,
                fcFxPortStackedConnMode,
                fcFxPortClass2SeqDeliv,
                fcFxPortClass3SeqDeliv,
                fcFxPortHoldTime }
        STATUS current
        DESCRIPTION
               "A collection of objects providing the configuration and service
                parameters of the Fabric Element, the modules, and FxPorts."
 -- 1.3.6.1.2.1.75.2.2.1 --  ::= { fcFeMIBGroups 1 }

fcFeStatusGroup OBJECT-GROUP
        OBJECTS {
                fcFxPortID,
                fcFxPortBbCreditAvailable,
                fcFxPortOperMode,
                fcFxPortAdminMode,
                fcFxPortPhysAdminStatus,
                fcFxPortPhysOperStatus,
                fcFxPortPhysLastChange,
                fcFxPortPhysRttov,
                fcFxPortFcphVersionAgreed,
                fcFxPortNxPortBbCredit,
                fcFxPortNxPortRxDataFieldSize,
                fcFxPortCosSuppAgreed,
                fcFxPortIntermixSuppAgreed,
                fcFxPortStackedConnModeAgreed,
                fcFxPortClass2SeqDelivAgreed,
                fcFxPortClass3SeqDelivAgreed,
                fcFxPortNxPortName,
                fcFxPortConnectedNxPort,
                fcFxPortBbCreditModel }
        STATUS current
        DESCRIPTION
               "A collection of objects providing the operational status and
                established service parameters for the Fabric Element and the
                attached NxPorts."
 -- 1.3.6.1.2.1.75.2.2.2 --  ::= { fcFeMIBGroups 2 }

fcFeErrorGroup OBJECT-GROUP
        OBJECTS {
                fcFxPortLinkFailures,
                fcFxPortSyncLosses,
                fcFxPortSigLosses,
                fcFxPortPrimSeqProtoErrors,
                fcFxPortInvalidTxWords,
                fcFxPortInvalidCrcs,
                fcFxPortDelimiterErrors,
                fcFxPortAddressIdErrors,
                fcFxPortLinkResetIns,
                fcFxPortLinkResetOuts,
                fcFxPortOlsIns,
                fcFxPortOlsOuts }
        STATUS current
        DESCRIPTION
               "A collection of objects providing various error
                statistics detected by the FxPorts."
 -- 1.3.6.1.2.1.75.2.2.3 --  ::= { fcFeMIBGroups 3 }

fcFeClass1AccountingGroup OBJECT-GROUP
        OBJECTS {
                fcFxPortC1InFrames,
                fcFxPortC1OutFrames,
                fcFxPortC1InOctets,
                fcFxPortC1OutOctets,
                fcFxPortC1Discards,
                fcFxPortC1FbsyFrames,
                fcFxPortC1FrjtFrames,
                fcFxPortC1InConnections,
                fcFxPortC1OutConnections,
                fcFxPortC1ConnTime }
        STATUS current
        DESCRIPTION
               "A collection of objects providing various class 1
                performance statistics detected by the FxPorts."
 -- 1.3.6.1.2.1.75.2.2.4 --  ::= { fcFeMIBGroups 4 }

fcFeClass2AccountingGroup OBJECT-GROUP
        OBJECTS {
                fcFxPortC2InFrames,
                fcFxPortC2OutFrames,
                fcFxPortC2InOctets,
                fcFxPortC2OutOctets,
                fcFxPortC2Discards,
                fcFxPortC2FbsyFrames,
                fcFxPortC2FrjtFrames }
        STATUS current
        DESCRIPTION
               "A collection of objects providing various class 2
                performance statistics detected by the FxPorts."
 -- 1.3.6.1.2.1.75.2.2.5 --  ::= { fcFeMIBGroups 5 }

fcFeClass3AccountingGroup OBJECT-GROUP
        OBJECTS {
                fcFxPortC3InFrames,
                fcFxPortC3OutFrames,
                fcFxPortC3InOctets,
                fcFxPortC3OutOctets,
                fcFxPortC3Discards }
        STATUS current
        DESCRIPTION
               "A collection of objects providing various class 3
                performance statistics detected by the FxPorts."
 -- 1.3.6.1.2.1.75.2.2.6 --  ::= { fcFeMIBGroups 6 }

fcFeCapabilitiesGroup OBJECT-GROUP
        OBJECTS {
                fcFxPortCapFcphVersionHigh,
                fcFxPortCapFcphVersionLow,
                fcFxPortCapBbCreditMax,
                fcFxPortCapBbCreditMin,
                fcFxPortCapRxDataFieldSizeMax,
                fcFxPortCapRxDataFieldSizeMin,
                fcFxPortCapCos,
                fcFxPortCapIntermix,
                fcFxPortCapStackedConnMode,
                fcFxPortCapClass2SeqDeliv,
                fcFxPortCapClass3SeqDeliv,
                fcFxPortCapHoldTimeMax,
                fcFxPortCapHoldTimeMin }
        STATUS current
        DESCRIPTION
               "A collection of objects providing the inherent
                capability of each FxPort within the Fabric Element."
 -- 1.3.6.1.2.1.75.2.2.7 --  ::= { fcFeMIBGroups 7 }

END
-- 
--    Copyright (C) The Internet Society (2000).  All Rights Reserved.
-- 
--    This document and translations of it may be copied and furnished to
--    others, and derivative works that comment on or otherwise explain it
--    or assist in its implementation may be prepared, copied, published
--    and distributed, in whole or in part, without restriction of any
--    kind, provided that the above copyright notice and this paragraph are
--    included on all such copies and derivative works.  However, this
--    document itself may not be modified in any way, such as by removing
--    the copyright notice or references to the Internet Society or other
--    Internet organizations, except as needed for the purpose of
--    developing Internet standards in which case the procedures for
--    copyrights defined in the Internet Standards process must be
--    followed, or as required to translate it into languages other than
--    English.
-- 
--    The limited permissions granted above are perpetual and will not be
--    revoked by the Internet Society or its successors or assigns.
-- 
--    This document and the information contained herein is provided on an
--    "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
--    TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
--    BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
--    HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
--    MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--